Suppr超能文献

用于从3D表面图像计算乳房体积的新软件和乳房边界标志。

New software and breast boundary landmarks to calculate breast volumes from 3D surface images.

作者信息

Wesselius T S, Vreeken R D, Verhulst A C, Xi T, Maal T J J, Ulrich D J O

机构信息

1Department of Plastic-, Reconstructive-, and Hand Surgery, Radboud University Medical Center, P.O. Box 9101, 6500 HB Nijmegen, the Netherlands.

2Radboudumc 3D Lab, Radboud University Medical Center, Nijmegen, the Netherlands.

出版信息

Eur J Plast Surg. 2018;41(6):663-670. doi: 10.1007/s00238-018-1431-2. Epub 2018 Jul 6.

Abstract

BACKGROUND

A method to accurately calculate breast volumes helps achieving a better breast surgery outcome. 3D surface imaging potentially allows these calculations in a harmless, quick, and practicable way. The calculated volume from a 3D surface image is dependent on the determined breast boundary and the method of chest wall simulation by software. Currently, there is no consensus on a robust set of breast boundary landmarks and validation studies on breast volume calculation software are scarce. The purposes of this study were to determine the robustness of newly introduced breast boundary landmarks and introduce and validate a new method to simulate a chest wall.

METHODS

Sixteen subjects who underwent a unilateral simple mastectomy were included. In addition to the natural skin fold of the breast, the sternomanubrial joint, the transition of the pectoral muscle curve into the breast curvature, and the midaxillary line were used as landmarks to indicate the breast boundary. The intra- and interrater variability of these landmarks was tested. Furthermore, new chest wall simulation software was validated on the breastless chest side of the subjects.

RESULTS

The intra- and interrater variability of the three breast boundary markers was small (mean 3.5-6.7 mm), and no significant difference was found between the intra- and interrater variability ( = 0.08,  = 0.06, and  = 0.10). The mean volume error of the most accurately simulated chest wall was 4.6 ± 37 ml.

CONCLUSION

The newly introduced landmarks showed to be robust and our new chest wall simulation algorithm showed accurate results.Level of Evidence: Level IV, diagnostic study.

摘要

背景

一种准确计算乳房体积的方法有助于实现更好的乳房手术效果。三维表面成像可能以无害、快速且可行的方式进行这些计算。从三维表面图像计算出的体积取决于确定的乳房边界以及软件模拟胸壁的方法。目前,对于一组可靠的乳房边界标志尚无共识,且关于乳房体积计算软件的验证研究也很匮乏。本研究的目的是确定新引入的乳房边界标志的可靠性,并介绍和验证一种模拟胸壁的新方法。

方法

纳入16例行单侧单纯乳房切除术的受试者。除了乳房的自然皮肤褶皱外,还将胸骨柄关节、胸大肌曲线向乳房曲线的过渡以及腋中线用作指示乳房边界的标志。测试了这些标志在评估者内和评估者间的变异性。此外,在受试者的无乳房侧对新的胸壁模拟软件进行了验证。

结果

三个乳房边界标记在评估者内和评估者间的变异性较小(平均3.5 - 6.7毫米),评估者内和评估者间变异性之间未发现显著差异( = 0.08, = 0.06, = 0.10)。模拟最准确的胸壁的平均体积误差为4.6±37毫升。

结论

新引入的标志显示出可靠性,且我们新的胸壁模拟算法显示出准确的结果。证据水平:IV级,诊断性研究。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dcdc/6244993/e62f7cac4e1c/238_2018_1431_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验