用于在分段伽马扫描仪中对大体积放射性废物桶进行检测的全能峰效率校准。

Full energy peak efficiency calibration for the assay of large volume radioactive waste drums in a segmented gamma scanner.

作者信息

Patra Sabyasachi, Agarwal Chhavi, Chaudhury Sanhita

机构信息

Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.

Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.

出版信息

Appl Radiat Isot. 2019 Feb;144:80-86. doi: 10.1016/j.apradiso.2018.11.014. Epub 2018 Nov 27.

Abstract

Large volume radioactive waste drums with low/intermediate level of alpha activity, generated in radiochemical laboratories, are in general screened for special nuclear materials (SNM) in a segmented gamma scanner (SGS) before disposal. The assay methodology traditionally requires a standard drum of identical geometry and thereby making the procedure relying on the availability of a true standard, which is often difficult to organize. Here, we report a non-conventional absolute segmented gamma scanning (ASGS) methodology for the assay of 200 L waste drums, avoiding the use of a standard drum. The present analysis employ the full energy peak (FEP) efficiency, ingeniously determined using a standard Eu point source. From combined experiment and Monte Carlo simulation, it has been established that, the FEP efficiencies of the detector for a 200 L cylindrical sample can be well reproduced using a point source. While verifying the applicability of the point source FEP efficiencies for the assay of plutonium in 200 L drums, an energy dependent bias has been seen, which confirms the presence of lump attenuation in addition to the general matrix attenuation. An infinite energy extrapolation of apparent mass approach has been adopted for the assay of large volume waste drums which takes care of the gamma-ray attenuation from all sources that is otherwise difficult to correct for in a sample drum of unknown history.

摘要

放射化学实验室产生的具有低/中级α放射性的大体积放射性废物桶,通常在处置前在分段伽马扫描仪(SGS)中对特殊核材料(SNM)进行筛查。传统的分析方法需要一个几何形状相同的标准桶,因此该程序依赖于真正标准的可用性,而这往往很难安排。在此,我们报告一种用于检测200升废物桶的非常规绝对分段伽马扫描(ASGS)方法,无需使用标准桶。本分析采用全能量峰(FEP)效率,巧妙地使用标准铕点源确定。通过结合实验和蒙特卡罗模拟,已确定使用点源可以很好地再现探测器对200升圆柱形样品的FEP效率。在验证点源FEP效率对200升桶中钚检测的适用性时,发现了能量依赖性偏差,这证实了除了一般的基质衰减外还存在块状衰减。对于大体积废物桶的检测,采用了表观质量方法的无限能量外推法,该方法考虑了来自所有源的伽马射线衰减,否则在历史未知的样品桶中很难校正这种衰减。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验