Faculty of Engineering, McMaster University, Hamilton, Canada.
Forsee Instruments Ltd., Hamilton, Canada.
Sci Rep. 2018 Dec 13;8(1):17808. doi: 10.1038/s41598-018-35970-8.
One of the biggest challenges in rapid low concentration bacterial detection is the pre-concentration or pre-enrichment, which aims to increase bacteria concentration and reduce sample volume for easy bacterial detection. In practical bacterial detection, large-volume water samples with a pathogenic bacterial concentration of less than 1 CFU/mL have to be tested rapidly. The reported biosensors either have insufficient detection limit or have limited capability of handling a sufficiently large water sample. Therefore, a high-performance automated pre-enrichment process is strongly demanded in rapid practical bacterial detection. In this paper, a practical high performance automated bacterial concentration and recovery system (ABCRS) based on the combination of a ceramic membrane and tangential flow filtration technique was presented with short processing time (less than one hour), low pre-enrichment limit (≤0.005 CFU/mL), high concentration ratio (≥ 500), high recovery efficiency (~ 90%), and small final retentate volume (≤ 5 mL).
快速低浓度细菌检测的最大挑战之一是预浓缩或预富集,其目的是增加细菌浓度并减少样本体积,以方便细菌检测。在实际的细菌检测中,必须快速检测具有低于 1 CFU/mL 致病性细菌浓度的大容量水样。已报道的生物传感器要么检测限不足,要么处理足够大容量水样的能力有限。因此,在快速实际的细菌检测中强烈需要高性能的自动预富集过程。本文提出了一种基于陶瓷膜和切向流过滤技术相结合的实用的高性能自动细菌浓缩和回收系统(ABCRS),其具有短处理时间(不到一个小时)、低预富集限度(≤0.005 CFU/mL)、高浓缩比(≥500)、高回收效率(约 90%)和小最终截留体积(≤5 mL)。