Suppr超能文献

使用惯性测量单元针对基于标记的光学三维运动捕捉系统进行足尖角度估计的验证。

Validation of foot pitch angle estimation using inertial measurement unit against marker-based optical 3D motion capture system.

作者信息

Sharif Bidabadi Shiva, Murray Iain, Lee Gabriel Yin Foo

机构信息

1Department of Mechanical Engineering, Curtin University of Technology, Perth, Australia.

2Department of Electrical and Computer Engineering, Curtin University of Technology, Perth, Australia.

出版信息

Biomed Eng Lett. 2018 May 17;8(3):283-290. doi: 10.1007/s13534-018-0072-5. eCollection 2018 Aug.

Abstract

Gait analysis is relevant to a broad range of clinical applications in areas of orthopedics, neurosurgery, rehabilitation and the sports medicine. There are various methods available for capturing and analyzing the gait cycle. Most of gait analysis methods are computationally expensive and difficult to implement outside the laboratory environment. Inertial measurement units, IMUs are considered a promising alternative for the future of gait analysis. This study reports the results of a systematic validation procedure to validate the foot pitch angle measurement captured by an IMU against Vicon Optical Motion Capture System, considered the standard method of gait analysis. It represents the first phase of a research project which aims to objectively evaluate the ankle function and gait patterns of patients with dorsiflexion weakness (commonly called a "drop foot") due to a L5 lumbar radiculopathy pre- and post-lumbar decompression surgery. The foot pitch angle of 381 gait cycles from 19 subjects walking trails on a flat surface have been recorded throughout the course of this study. Comparison of results indicates a mean correlation of 99.542% with a standard deviation of 0.834%. The maximum root mean square error of the foot pitch angle measured by the IMU compared with the Vicon Optical Motion Capture System was 3.738° and the maximum error in the same walking trail between two measurements was 9.927°. These results indicate the level of correlation between the two systems.

摘要

步态分析与骨科、神经外科、康复医学和运动医学等广泛的临床应用相关。有多种方法可用于捕捉和分析步态周期。大多数步态分析方法计算成本高昂,且难以在实验室环境之外实施。惯性测量单元(IMU)被认为是未来步态分析的一种有前途的替代方法。本研究报告了一项系统验证程序的结果,该程序旨在针对被视为步态分析标准方法的Vicon光学运动捕捉系统,验证由IMU捕获的足部俯仰角测量值。它代表了一个研究项目的第一阶段,该项目旨在客观评估因L5腰椎神经根病导致背屈肌无力(通常称为“垂足”)的患者在腰椎减压手术前后的踝关节功能和步态模式。在本研究过程中,记录了19名受试者在平坦表面行走轨迹的381个步态周期的足部俯仰角。结果比较表明,平均相关性为99.542%,标准差为0.834%。与Vicon光学运动捕捉系统相比,IMU测量的足部俯仰角的最大均方根误差为3.738°,同一步行轨迹两次测量之间的最大误差为9.927°。这些结果表明了两个系统之间的相关程度。

相似文献

1
Validation of foot pitch angle estimation using inertial measurement unit against marker-based optical 3D motion capture system.
Biomed Eng Lett. 2018 May 17;8(3):283-290. doi: 10.1007/s13534-018-0072-5. eCollection 2018 Aug.
2
Inertial measurement unit compared to an optical motion capturing system in post-stroke individuals with foot-drop syndrome.
Ann Phys Rehabil Med. 2020 May;63(3):195-201. doi: 10.1016/j.rehab.2019.03.007. Epub 2019 Apr 19.
4
The application of inertial measurements unit for the clinical evaluation and assessment of gait events.
J Med Eng Technol. 2017 Nov;41(8):612-622. doi: 10.1080/03091902.2017.1382588. Epub 2017 Oct 5.
5
Can inertial measurement unit sensors evaluate foot kinematics in drop foot patients using functional electrical stimulation?
Front Hum Neurosci. 2023 Nov 9;17:1225086. doi: 10.3389/fnhum.2023.1225086. eCollection 2023.
6
Measuring highly accurate foot position and angle trajectories with foot-mounted IMUs in clinical practice.
Gait Posture. 2024 Feb;108:63-69. doi: 10.1016/j.gaitpost.2023.11.002. Epub 2023 Nov 4.
7
Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems.
Ann Rehabil Med. 2018 Dec;42(6):872-883. doi: 10.5535/arm.2018.42.6.872. Epub 2018 Dec 28.
8
A multi-segment modelling approach for foot trajectory estimation using inertial sensors.
Gait Posture. 2020 Jan;75:22-27. doi: 10.1016/j.gaitpost.2019.09.022. Epub 2019 Sep 22.
9
Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis.
Front Physiol. 2020 Jan 10;10:1530. doi: 10.3389/fphys.2019.01530. eCollection 2019.

引用本文的文献

1
A Multi-sensor Gait Dataset Collected Under Non-standardized Dual-Task Conditions.
Sci Data. 2025 Jul 1;12(1):1121. doi: 10.1038/s41597-025-05458-y.
2
Kinematics of Topspin Stroke Combinations in Table Tennis and its Inter-Individual Variability.
J Sports Sci Med. 2025 Jun 1;24(2):311-325. doi: 10.52082/jssm.2025.311. eCollection 2025 Jun.
5
Designing Ecological Auditory Feedback on Lower Limb Kinematics for Hemiparetic Gait Training.
Sensors (Basel). 2023 Apr 13;23(8):3964. doi: 10.3390/s23083964.
7
Vibrotactile somatosensory stimulus to assist the transition from level walking to stair ascent in the elderly: a pilot study.
BMC Musculoskelet Disord. 2022 Feb 24;22(Suppl 1):1066. doi: 10.1186/s12891-022-05093-3.
8
Effect of local somatosensory stimulus on postural sway during sit-to-stand movement in the elderly.
BMC Musculoskelet Disord. 2021 Nov 12;22(Suppl 1):731. doi: 10.1186/s12891-021-04609-7.
10
Remote Patient Monitoring with Wearable Sensors Following Knee Arthroplasty.
Sensors (Basel). 2021 Jul 29;21(15):5143. doi: 10.3390/s21155143.

本文引用的文献

1
The application of inertial measurements unit for the clinical evaluation and assessment of gait events.
J Med Eng Technol. 2017 Nov;41(8):612-622. doi: 10.1080/03091902.2017.1382588. Epub 2017 Oct 5.
2
Measuring 3D Hand and Finger Kinematics-A Comparison between Inertial Sensing and an Opto-Electronic Marker System.
PLoS One. 2016 Nov 3;11(11):e0164889. doi: 10.1371/journal.pone.0164889. eCollection 2016.
3
Novel Foot Progression Angle Algorithm Estimation via Foot-Worn, Magneto-Inertial Sensing.
IEEE Trans Biomed Eng. 2016 Nov;63(11):2278-2285. doi: 10.1109/TBME.2016.2523512. Epub 2016 Jan 29.
4
Gait analysis using wearable sensors.
Sensors (Basel). 2012;12(2):2255-83. doi: 10.3390/s120202255. Epub 2012 Feb 16.
5
Repeatability of an off-the-shelf, full body inertial motion capture system during clinical gait analysis.
Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:5125-8. doi: 10.1109/IEMBS.2010.5626196.
6
Systematic accuracy and precision analysis of video motion capturing systems--exemplified on the Vicon-460 system.
J Biomech. 2008 Aug 28;41(12):2776-80. doi: 10.1016/j.jbiomech.2008.06.024. Epub 2008 Jul 30.
7
The reliability of using accelerometer and gyroscope for gait event identification on persons with dropped foot.
Gait Posture. 2008 Feb;27(2):248-57. doi: 10.1016/j.gaitpost.2007.03.018. Epub 2007 May 21.
8
Gait analysis methods in rehabilitation.
J Neuroeng Rehabil. 2006 Mar 2;3:4. doi: 10.1186/1743-0003-3-4.
9
Ambulatory measurement of arm orientation.
J Biomech. 2007;40(1):78-85. doi: 10.1016/j.jbiomech.2005.11.011. Epub 2006 Feb 7.
10
Stair climbing detection during daily physical activity using a miniature gyroscope.
Gait Posture. 2005 Dec;22(4):287-94. doi: 10.1016/j.gaitpost.2004.08.008. Epub 2004 Dec 29.