Suppr超能文献

印模材料和托盘对成角种植体印模准确性影响的比较评估

Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions.

作者信息

Siadat Hakimeh, Saeidi Zeinab, Alikhasi Marzieh, Zeighami Somayeh

机构信息

DDS, MSc; Full Professor, Dental Implant Research Center Dentistry Research Institute and Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.

DDS, MSc; Assistant Professor, Department of Prosthodontics, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran.

出版信息

J Clin Exp Dent. 2018 Nov 1;10(11):e1096-e1102. doi: 10.4317/jced.55227. eCollection 2018 Nov.

Abstract

BACKGROUND

Vinyl Polyether Siloxane is a newly introduced impression material and studies on that is scarce. Implant insertion in posterior mandible might be angulated due to anatomical considerations. The purpose of this study was to compare the dimensional and angular accuracy of impressions using full-arch versus sectional tray and Vinyl Polysiloxane versus Vinyl Polyether Siloxane in angulated implants.

MATERIAL AND METHODS

Four implants were placed in dental areas #19, #21, #28 and #30 of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty sectional and 20 full-arch open trays were made on the primary cast. Impressions were taken using Vinyl Polysiloxane and Vinyl Polyether Siloxane (n=10 in 4 groups); and were poured with type IV dental stone. The coordinate measuring machine was used to measure displacements in the X, Y and Z axes and rotational discrepancies of implants. The data were analyzed using SPSS 22 and two-way ANOVA.

RESULTS

Type of tray had no significant effect on the dimensional and angular accuracy of impressions ( >0.05). Type of impression material significantly affected linear displacement (∆r) ( <0.05); but it did not significantly affect the rotational displacement ( >0.05).

CONCLUSIONS

Vinyl Polysiloxane yielded more accurate impressions of angulated implants. Dental implant, impression material, impression tray, vinyl polysiloxane, vinyl polyether silicone, coordinate measuring machine.

摘要

背景

乙烯基聚醚硅氧烷是一种新引入的印模材料,相关研究较少。由于解剖学因素,下颌后部植入物的植入可能会有一定角度。本研究的目的是比较在有角度的种植体中,使用全牙弓托盘与分段托盘以及乙烯基聚硅氧烷与乙烯基聚醚硅氧烷制取的印模的尺寸和角度精度。

材料与方法

在一个具有30°舌侧角度的肯尼迪I类下颌丙烯酸模型的19、21、28和30号牙位区域植入4颗种植体。在初模型上制作20个分段托盘和20个全牙弓开放式托盘。使用乙烯基聚硅氧烷和乙烯基聚醚硅氧烷(4组中每组n = 10)制取印模;并用IV型牙科石膏灌注。使用坐标测量机测量种植体在X、Y和Z轴上的位移以及旋转差异。使用SPSS 22软件和双向方差分析对数据进行分析。

结果

托盘类型对印模的尺寸和角度精度没有显著影响(P>0.05)。印模材料类型对线性位移(∆r)有显著影响(P<0.05);但对旋转位移没有显著影响(P>0.05)。

结论

乙烯基聚硅氧烷制取的有角度种植体印模更精确。牙种植体、印模材料、印模托盘、乙烯基聚硅氧烷、乙烯基聚醚硅氧烷、坐标测量机。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d940/6311409/d6a3a6e3126b/jced-10-e1096-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验