Accuracy of 3 different impression techniques for internal connection angulated implants.

作者信息

Tsagkalidis George, Tortopidis Dimitrios, Mpikos Pavlos, Kaisarlis George, Koidis Petros

机构信息

Postgraduate student, Department of Fixed Prosthesis and Implant Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Assistant Professor, Department of Fixed Prosthesis and Implant Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.

出版信息

J Prosthet Dent. 2015 Oct;114(4):517-23. doi: 10.1016/j.prosdent.2015.05.005. Epub 2015 Jul 26.

Abstract

STATEMENT OF PROBLEM

Making implant impressions with different angulations requires a more precise and time-consuming impression technique.

PURPOSE

The purpose of this in vitro study was to compare the accuracy of nonsplinted, splinted, and snap-fit impression techniques of internal connection implants with different angulations.

MATERIAL AND METHODS

An experimental device was used to allow a clinical simulation of impression making by means of open and closed tray techniques. Three different impression techniques (nonsplinted, acrylic-resin splinted, and indirect snap-fit) for 6 internal-connected implants at different angulations (0, 15, 25 degrees) were examined using polyether. Impression accuracy was evaluated by measuring the differences in 3-dimensional (3D) position deviations between the implant body/impression coping before the impression procedure and the coping/laboratory analog positioned within the impression, using a coordinate measuring machine. Data were analyzed by 2-way ANOVA. Means were compared with the least significant difference criterion at P<.05.

RESULTS

Results showed that at 25 degrees of implant angulation, the highest accuracy was obtained with the splinted technique (mean ±SE: 0.39 ±0.05 mm) and the lowest with the snap-fit technique (0.85 ±0.09 mm); at 15 degrees of angulation, there were no significant differences among splinted (0.22 ±0.04 mm) and nonsplinted technique (0.15 ±0.02 mm) and the lowest accuracy obtained with the snap-fit technique (0.95 ±0.15 mm); and no significant differences were found between nonsplinted and splinted technique at 0 degrees of implant placement.

CONCLUSIONS

Splinted impression technique exhibited a higher accuracy than the other techniques studied when increased implant angulations at 25 degrees were involved.

摘要

问题陈述

使用不同角度进行种植体印模制取需要更精确且耗时的印模技术。

目的

本体外研究的目的是比较不同角度的内连接种植体的非夹板式、夹板式和卡扣式印模技术的准确性。

材料与方法

使用一种实验装置,通过开放托盘和封闭托盘技术进行临床印模制取模拟。使用聚醚对6个不同角度(0°、15°、25°)的内连接种植体的三种不同印模技术(非夹板式、丙烯酸树脂夹板式和间接卡扣式)进行检测。通过使用坐标测量机测量印模制取前种植体主体/印模帽与印模内的帽/实验室模型之间三维(3D)位置偏差的差异来评估印模准确性。数据采用双向方差分析进行分析。采用最小显著差法在P<0.05时比较均值。

结果

结果显示,在种植体角度为25°时,夹板式技术获得的准确性最高(均值±标准误:0.39±0.05mm),卡扣式技术最低(0.85±0.09mm);在角度为15°时,夹板式(0.22±0.04mm)和非夹板式技术(0.15±0.02mm)之间无显著差异,卡扣式技术获得的准确性最低(0.95±0.15mm);在种植体植入角度为0°时,非夹板式和夹板式技术之间未发现显著差异。

结论

当种植体角度增加到25°时,夹板式印模技术比其他研究技术表现出更高的准确性。