镓枸橼酸盐PET/CT在检测下肢感染性假体中的潜在用途。

Potential usefulness of Ga-citrate PET/CT in detecting infected lower limb prostheses.

作者信息

Tseng Jing-Ren, Chang Yu-Han, Yang Lan-Yan, Wu Chen-Te, Chen Szu-Yuan, Wan Chih-Hsing, Hsiao Ing-Tsung, Yen Tzu-Chen

机构信息

Department of Nuclear Medicine and Center for Advanced Molecular Imaging and Translation, Chang Gung Memorial Hospital at Linkou, No. 5, Fu-Hsing ST., Kwei-Shan, Taoyuan, Taiwan.

Department of Medical Imaging and Radiological Science and Healthy Aging Center, College of Medicine, Chang Gung University, Taoyuan, Taiwan.

出版信息

EJNMMI Res. 2019 Jan 3;9(1):2. doi: 10.1186/s13550-018-0468-3.

Abstract

BACKGROUND

Prosthetic joint infections may lead to failures of total joint arthroplasty. Radionuclide imaging can play a diagnostic role in identifying such infections, which require two-stage exchange arthroplasty (instead of simple revision surgery performed in non-infected cases). Although F-FDG PET/CT has emerged as a novel diagnostic tool in this setting, the clinical usefulness of Ga-citrate PET/CT has not been previously investigated. This single-center prospective study was designed to address this issue.

METHODS

Between January 2016 and October 2017, we examined 34 patients with clinically proven or suspected prosthetic hip/knee joint infections scheduled to undergo surgery. All patients underwent Ga-citrate PET/CT scans and sequential F-FDG PET/CT imaging for comparative purposes. Intraoperative findings and the results of microbiological analyses of surgical specimens served as gold standard. The diagnostic results were examined according to (1) image interpretation based on radiotracer uptake patterns and (2) quantitative analysis using volumes of interest (VOIs) to calculate standard uptake values (SUVs) and metabolic volumes (MVs).

RESULTS

A total of 26 (76%) patients were diagnosed as having infections. Based on radiotracer uptake pattern criteria, the sensitivity, specificity, and accuracy of Ga-citrate PET/CT and F-FDG PET/CT were 92%, 88%, and 91% and 100%, 38%, and 85%, respectively. MV was significantly higher in the infected group when Ga-citrate PET/CT was used (422.45 vs. 303.65 cm, p = 0.027), whereas no significant differences were observed on F-FDG PET/CT. According to receiver operating characteristic (ROC) curve analysis, a cut-off value of 370.86 for MV resulted in a sensitivity of 61.5% and a specificity of 87.5% (area under curve: 0.75, 95% confidence interval: 0.57-0.88, p = 0.035).

CONCLUSIONS

Subject to future confirmation, our data provide preliminary evidence that Ga-citrate PET/CT may have a complimentary role to F-FDG PET/CT in detecting prosthetic joint infections, being characterized by a higher specificity and the possibility to discriminate between an infectious condition and sterile inflammation.

TRIAL REGISTRATION

This prospective study was registered at clinicaltrials.gov (registration number: NCT02855190 ).

摘要

背景

人工关节感染可能导致全关节置换术失败。放射性核素成像在识别此类感染方面可发挥诊断作用,此类感染需要两阶段关节置换术(而非在未感染病例中进行的单纯翻修手术)。尽管F-FDG PET/CT已成为这一领域的新型诊断工具,但此前尚未研究过枸橼酸镓PET/CT的临床应用价值。本单中心前瞻性研究旨在解决这一问题。

方法

2016年1月至2017年10月期间,我们对34例临床确诊或疑似人工髋关节/膝关节感染且计划接受手术的患者进行了检查。为作比较,所有患者均接受了枸橼酸镓PET/CT扫描及序贯F-FDG PET/CT成像。术中发现及手术标本的微生物分析结果作为金标准。根据(1)基于放射性示踪剂摄取模式的图像解读和(2)使用感兴趣区(VOI)计算标准摄取值(SUV)和代谢体积(MV)的定量分析来检查诊断结果。

结果

共有26例(76%)患者被诊断为感染。基于放射性示踪剂摄取模式标准,枸橼酸镓PET/CT和F-FDG PET/CT的敏感性、特异性和准确性分别为92%、88%和91%以及100%、38%和85%。使用枸橼酸镓PET/CT时,感染组的MV显著更高(422.45对303.65 cm,p = 0.027),而在F-FDG PET/CT上未观察到显著差异。根据受试者工作特征(ROC)曲线分析,MV的截断值为370.86时,敏感性为61.5%,特异性为87.5%(曲线下面积:0.75,95%置信区间:0.57 - 0.88,p = 0.035)。

结论

有待进一步证实,我们的数据提供了初步证据,表明枸橼酸镓PET/CT在检测人工关节感染方面可能对F-FDG PET/CT起到补充作用,其特点是特异性更高,且有可能区分感染状态和无菌性炎症。

试验注册

本前瞻性研究已在clinicaltrials.gov注册(注册号:NCT02855190)。