Suppr超能文献

Bio-C Pulpecto 的生物相容性和生物矿化能力:组织学和免疫组织化学研究。

Biocompatibility and biomineralization ability of Bio-C Pulpecto. A histological and immunohistochemical study.

机构信息

Department of Restorative Dentistry, Araçatuba Dental School, Endodontics, UNESP-Univ Estadual Paulista, Araçatuba, São Paulo, Brazil.

Department of Clinics and Surgery, School of Dentistry, Federal University of Alfenas (UNIFAL-MG), Alfenas, Minas Gerais, Brazil.

出版信息

Int J Paediatr Dent. 2019 May;29(3):352-360. doi: 10.1111/ipd.12464. Epub 2019 Feb 1.

Abstract

AIM

To evaluate the inflammatory response, biomineralization and production of osteocalcin (OCN), osteopontin (OPN), and bone sialoprotein (BSP) of a new root filling material for primary teeth (Bio-C Pulpecto) compared to MTA.

DESIGN

Polyethylene tubes containing Bio-C Pulpecto, MTA, and empty tubes were implanted into the dorsal connective tissue. After 7, 15, 30, 60, and 90 days, the tubes with surrounding tissue were removed and histologically processed to be analysed using haematoxylin and eosin, von Kossa staining, or no staining for observation under polarized light and immunohistochemistry for the detection of OCN, OPN, and BSP. The Kruskal-Wallis test was used followed by Dunn's test. The significance level was set at 5%.

RESULTS

The inflammatory response observed with MTA and Bio-C Pulpecto was more exacerbated until the 15th day and decreased from 30 days on. No significant difference was found between control, MTA, and Bio-C Pulpecto (P > 0.05). Bio-C Pulpecto and MTA showed positivity for von Kossa and birefringent to polarized light. The immunolabelling for OCN, OPN, and BSP was more intense for MTA and Bio-C Pulpecto on days 60 and 90 (P > 0.05).

CONCLUSION

Bio-C Pulpecto was biocompatible, induced biomineralization and was immunopositive for osteogenic markers such as OCN, OPN, and BSP, similarly to MTA.

摘要

目的

评价新型乳牙根管充填材料(Bio-C Pulpecto)与 MTA 的炎症反应、生物矿化以及骨钙素(OCN)、骨桥蛋白(OPN)和骨涎蛋白(BSP)的产生。

设计

将含有 Bio-C Pulpecto、MTA 和空管的聚乙烯管植入背部结缔组织。在第 7、15、30、60 和 90 天,取出带有周围组织的管,进行组织学处理,用苏木精和伊红、von Kossa 染色或不染色,在偏光显微镜下观察,并进行 OCN、OPN 和 BSP 的免疫组织化学检测。采用 Kruskal-Wallis 检验,然后用 Dunn 检验。显著性水平设为 5%。

结果

用 MTA 和 Bio-C Pulpecto 观察到的炎症反应在第 15 天更为加剧,从第 30 天开始减少。与对照组相比,MTA 和 Bio-C Pulpecto 之间无显著差异(P>0.05)。Bio-C Pulpecto 和 MTA 在 von Kossa 染色和偏光下呈双折射阳性。在第 60 和 90 天,MTA 和 Bio-C Pulpecto 的 OCN、OPN 和 BSP 的免疫标记更为强烈(P>0.05)。

结论

Bio-C Pulpecto 具有生物相容性,诱导生物矿化,并对骨钙素、骨桥蛋白和骨涎蛋白等成骨标志物呈免疫阳性,与 MTA 相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验