Suppr超能文献

实时三维与二维双平面超声心动图评估黏液瘤样二尖瓣疾病犬左心房容积的比较

Comparison between real-time 3-dimensional and 2-dimensional biplane echocardiographic assessment of left atrial volumes in dogs with myxomatous mitral valve disease.

作者信息

Tidholm Anna, Bodegård-Westling Anna, Höglund Katja, Häggström Jens, Ljungvall Ingrid

机构信息

Anicura Albano Animal Hospital, Danderyd, Sweden.

Department of Clinical Sciences, Faculty of Veterinary Medicine, Swedish University of Agricultural Sciences, Uppsala, Sweden.

出版信息

J Vet Intern Med. 2019 Mar;33(2):455-461. doi: 10.1111/jvim.15408. Epub 2019 Jan 9.

Abstract

BACKGROUND

Assessment of left atrial (LA) size is important in medical decision making and prognostication in dogs with myxomatous mitral valve disease (MMVD). Real-time 3-dimensional (RT3DE) and 2-dimensional echocardiographic (2DE) methods may be used to assess LA size.

OBJECTIVES

To compare measured LA volumes obtained by RT3DE with those calculated by biplane Simpson's modified method of discs (SMOD) and the area-length method (ALM) using the same RT3DE acquisition with the same timing.

ANIMALS

One hundred twenty-one privately owned dogs with naturally occurring MMVD.

METHODS

Prospective observational study comparing LA volumes indexed to body weight using RT3DE and 2DE-based biplane SMOD and ALM. Agreement between methods was evaluated using Bland-Altman plots and linear regression analyses.

RESULTS

Estimations of LA volume using SMOD or ALM did not show good agreement with RT3DE-derived measurements. Absolute differences between methods increased with increasing LA volume, but SMOD underestimated whereas ALM overestimated calculated volumes compared to RT3DE-derived measurements. The difference in LA volume between RT3DE and the biplane methods showed a systematic underestimation of 7% for SMOD and a systematic overestimation of 24% for ALM. Comparison of LA volumes obtained by SMOD and ALM did not show good agreement. The ALM yielded 30% larger LA volumes compared to SMOD.

CONCLUSION AND CLINICAL IMPORTANCE

In comparison with RT3DE, SMOD systematically underestimated whereas ALM systematically overestimated LA volumes in dogs with MMVD. Because the systematic difference between RT3DE and SMOD was only 7%, SMOD might be considered the method of choice.

摘要

背景

在患有黏液瘤性二尖瓣疾病(MMVD)的犬类中,评估左心房(LA)大小对于医疗决策和预后判断很重要。实时三维(RT3DE)和二维超声心动图(2DE)方法可用于评估LA大小。

目的

使用相同的RT3DE采集并在相同时间点,比较通过RT3DE测量获得的LA容积与通过双平面辛普森改良圆盘法(SMOD)和面积-长度法(ALM)计算得出的LA容积。

动物

121只自然发生MMVD的私人饲养犬。

方法

前瞻性观察性研究,比较使用RT3DE以及基于2DE的双平面SMOD和ALM得出的体重指数化LA容积。使用布兰德-奥特曼图和线性回归分析评估方法之间的一致性。

结果

使用SMOD或ALM对LA容积的估计与RT3DE得出的测量值之间未显示出良好的一致性。随着LA容积增加,方法之间的绝对差异增大,但与RT3DE得出的测量值相比,SMOD低估了计算出的容积,而ALM高估了计算出的容积。RT3DE与双平面方法之间的LA容积差异显示,SMOD系统性低估了7%,ALM系统性高估了24%。比较SMOD和ALM获得的LA容积未显示出良好的一致性。与SMOD相比,ALM得出的LA容积大30%。

结论及临床意义

与RT3DE相比,在患有MMVD的犬类中,SMOD系统性低估而ALM系统性高估LA容积。由于RT3DE与SMOD之间的系统性差异仅为7%,SMOD可能被视为首选方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1dfc/6430916/05a11180d217/JVIM-33-455-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验