Suppr超能文献

前节光学相干断层扫描(AS-OCT)作为一种检测威尔逊病患者形成凯-弗环的铜沉积的新方法。

Anterior segment optical coherence tomography (AS-OCT) as a new method of detecting copper deposits forming the Kayser-Fleischer ring in patients with Wilson disease.

机构信息

SPKSO Ophthalmic University Hospital, Medical University of Warsaw, Warsaw, Poland.

2nd Department of Neurology, Institute of Psychiatry and Neurology, Warsaw, Poland.

出版信息

Acta Ophthalmol. 2019 Aug;97(5):e757-e760. doi: 10.1111/aos.14009. Epub 2019 Jan 11.

Abstract

PURPOSE

Kayser-Fleischer ring pathognomonic for Wilson disease (WD) is formed of corneal copper deposits present predominantly within the anterior chamber angle at the Schwalbe's line. The slit-lamp assessment commonly used as a standard of care cannot detect them early enough, as the angle view is obscured by the corneal limbus. The aim of the research was to evaluate the anterior segment optical coherence tomography (AS-OCT), as objective diagnostic assessment of copper deposits forming KF ring in patients with WD.

METHODS

Twenty-nine subjects (17 women) and twenty-nine controls (14 women) were enrolled and underwent slit lamp and AS-OCT assessment.

RESULTS

Kayser-Fleischer ring was not detected - either with a slit lamp or with AS-OCT - in any of the controls. Fifteen subjects presenting without KF ring at a slit-lamp examination were found to have a KF ring when examined with AS-OCT (p < 0.001), which confirms improved accuracy of AS-OCT, as compared to the slit-lamp examination.

CONCLUSION

Our results support AS-OCT as a diagnostic procedure to offer better objectivity and accuracy as compared to a slit-lamp examination, both at the diagnostic stage and when monitoring changes in KF ring during medical therapy to assess its efficacy and patient compliance.

摘要

目的

凯-弗二氏环是肝豆状核变性(WD)的特征性表现,由角膜铜沉积形成,主要位于 Schwalbe 线前房角处。作为常规护理标准的裂隙灯检查不能足够早地发现它们,因为角膜缘遮挡了角视图。本研究旨在评估眼前节光学相干断层扫描(AS-OCT)作为肝豆状核变性患者形成 KF 环的铜沉积的客观诊断评估。

方法

共纳入 29 名受试者(17 名女性)和 29 名对照者(14 名女性),并进行了裂隙灯和 AS-OCT 评估。

结果

在任何对照者中,均未通过裂隙灯或 AS-OCT 检测到凯-弗二氏环。在裂隙灯检查中未发现 KF 环的 15 名受试者,在 AS-OCT 检查中发现存在 KF 环(p<0.001),这证实了 AS-OCT 较裂隙灯检查具有更高的准确性。

结论

我们的结果支持 AS-OCT 作为一种诊断程序,与裂隙灯检查相比,在诊断阶段以及在医疗治疗期间监测 KF 环变化以评估其疗效和患者依从性时,提供更好的客观性和准确性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验