• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comparison of the Medtronic SelectSecure and conventional pacing leads: Long-term follow-up in a multicenter pediatric and congenital cohort.

作者信息

Moak Jeffrey P, Law Ian H, LaPage Martin J, Fish Frank, Shatty Ira, Dubin Anne M, Patel Akash, Fishbach Peter, Cain Nicole, Johnsrude Christopher, Berul Charles I, Bangoura Aminata, Hanumanthaiah Sridhar, McCarter Robert

机构信息

Division of Cardiology, Children's National Health System, Washington, DC.

Division of Pediatric Cardiology, University of Iowa, Stead Family Children's Hospital, Iowa City, Iowa.

出版信息

Pacing Clin Electrophysiol. 2019 Mar;42(3):356-365. doi: 10.1111/pace.13614. Epub 2019 Feb 8.

DOI:10.1111/pace.13614
PMID:30680764
Abstract

INTRODUCTION

The Medtronic SelectSecure™ (Minneapolis, MN, USA) pacing lead (SS) has theoretical advantages compared to conventional (C) transvenous pacing leads (PLs). The study purpose was to determine whether differences in electrical function and lead survival exist between these PLs in a large data set of pediatric and congenital patients.

METHODS

A multicenter historical longitudinal cohort study was performed comparing SS and CPL performance over a 72-month follow-up (FU). Ten centers provided data for both SS and CPL, matched for age, implanted pacing chamber, time period of implantation, and presence of heart disease.

RESULTS

The cohort consisted of 141 subjects in each group. No statistical differences were observed in age, gender, presence of heart disease, or pacing indication. Atrial and ventricular capture thresholds were stable throughout FU and higher in the SS group (atrial: 0.75 ± 0.02 vs 0.5 ± 0.04 V, ventricular: 1.0 ± 0.04 vs 0.75 ± 0.04 V), P < 0.001. Group PL sensing thresholds did not differ. The SS group required greater energy to pace (atrial: 0.57 ± 0.05 vs 0.32 ± 0.02 mJ, ventricular: 0.83 ± 0.05 vs 0.56 ± 0.06 mJ), P = 0.001. Early lead dislodgement and phrenic nerve stimulation were greater in the SS group (P = 0.03). Long-term lead survival was high and similar between the two groups, P = 0.35.

CONCLUSIONS

Long-term survival of both PL was high with a low fracture rate. The SS had excellent electrical function but did show higher capture thresholds and increased energy to pace; these differences are offset by other advantages of the SS PL.

摘要

相似文献

1
Comparison of the Medtronic SelectSecure and conventional pacing leads: Long-term follow-up in a multicenter pediatric and congenital cohort.
Pacing Clin Electrophysiol. 2019 Mar;42(3):356-365. doi: 10.1111/pace.13614. Epub 2019 Feb 8.
2
A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children.儿童双极类固醇洗脱心外膜起搏导线的12年经验
Ann Thorac Surg. 2008 May;85(5):1704-11. doi: 10.1016/j.athoracsur.2008.02.016.
3
Evaluation of different lead types and implantation techniques in pediatric populations with permanent pacemakers: Single-center with 10 years' experience.评价不同类型的电极导线并分析其在儿童永久性心脏起搏器植入术中的应用:单中心十年经验
Pacing Clin Electrophysiol. 2021 Jan;44(1):110-119. doi: 10.1111/pace.14126. Epub 2020 Dec 1.
4
Initial experience of pacing with a lumenless lead system in patients with congenital heart disease.先天性心脏病患者使用无腔导线系统起搏的初步经验。
Pacing Clin Electrophysiol. 2009 Nov;32(11):1428-33. doi: 10.1111/j.1540-8159.2009.02487.x. Epub 2009 Sep 21.
5
Efficacy of prophylactic epicardial pacing leads in children and young adults.预防性心外膜起搏导线在儿童和年轻成人中的疗效。
Ann Thorac Surg. 2004 Jul;78(1):197-202; discussion 202-3. doi: 10.1016/j.athoracsur.2004.02.008.
6
Ten-Year Clinical Experience with the Lumenless, Catheter-Delivered, 4.1-Fr Diameter Pacing Lead in Patients with and without Congenital Heart.无腔、经导管输送的4.1法国直径起搏导线在有和无先天性心脏病患者中的十年临床经验。
Pacing Clin Electrophysiol. 2017 Jan;40(1):17-25. doi: 10.1111/pace.12995. Epub 2017 Jan 17.
7
Long-term performance of bipolar epicardial atrial pacing using an active fixation bipolar endocardial lead.使用主动固定双极心内膜导线进行双极心外膜心房起搏的长期性能
Pacing Clin Electrophysiol. 1998 May;21(5):1098-104. doi: 10.1111/j.1540-8159.1998.tb00156.x.
8
Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.先天性心脏病合并先天性房室传导阻滞患者中,SelectSecure导线与传统起搏导线的拔除情况比较
Heart Rhythm. 2015 Jun;12(6):1227-32. doi: 10.1016/j.hrthm.2015.03.004. Epub 2015 Mar 5.
9
Lumenless pacing leads: performance and extraction in pediatrics and congenital heart disease.无腔静脉起搏导线:在儿科和先天性心脏病中的性能与取出
Pacing Clin Electrophysiol. 2015 Jan;38(1):42-7. doi: 10.1111/pace.12508. Epub 2014 Sep 16.
10
Twenty years experience with pediatric pacing: epicardial and transvenous stimulation.小儿起搏二十年经验:心外膜和经静脉刺激
Eur J Cardiothorac Surg. 2000 Apr;17(4):455-61. doi: 10.1016/s1010-7940(00)00364-x.