An origami paper-based electrochemical immunoassay for C-reactive protein (CRP) detection is described. The assay integrates multiple steps of electrode modification into a single device. A graphene-modified screen-printed carbon electrode (G/SPCE) was employed to enhance sensitivity. Gold nanoparticles were first electrodeposited onto the G/SPCE, followed by a self-assembled monolayer of L-cysteine. The capture anti-CRP was then covalently immobilized on the modified electrode. CRP was quantified by measuring the changes in the charge-transfer resistance of the electrode by using hexacyanoferrate as the redox probe. Cyclic voltammetry and scanning electron microscopy were also applied to verify the successful modification of the electrode. Under optimal conditions, impedance increase in the 0.05-100 μg mL CRP concentration range, and the limit of detection is 15 ng mL (at S/N = 3). The immunoassay was successfully applied to the determination of CRP in a certified human serum sample. This method is simple, low-cost, portable and disposable. Graphical abstract An origami paper-based analytical device (oPAD) is described that integrates the multistep of electrode modification, immobilization and detection into a single device. The direct conjugation between the capture antibody and target molecule was allowed to use in this system. The C-reactive protein (CRP) concentration in serum samples was determined using electrochemical impedance spectroscopy.
一种基于折纸的纸质电化学免疫分析用于检测 C-反应蛋白(CRP)。该分析将多个电极修饰步骤集成到单个设备中。采用石墨烯修饰的丝网印刷碳电极(G/SPCE)来提高灵敏度。首先将金纳米粒子电沉积在 G/SPCE 上,然后自组装 L-半胱氨酸单层。然后将捕获抗 CRP 通过使用铁氰化钾作为氧化还原探针来测量电极的电荷转移电阻的变化来定量。还应用循环伏安法和扫描电子显微镜来验证电极的成功修饰。在最佳条件下,在 0.05-100μg mL CRP 浓度范围内的阻抗增加,检测限为 15ng mL(信噪比=3)。该免疫分析成功应用于测定认证的人血清样品中的 CRP。该方法简单、低成本、便携且一次性。