Suppr超能文献

一种用于检测肉类样品中挥发性亚硝胺的优化顶空固相微萃取-气相色谱-质谱联用方法。

An optimised HS-SPME-GC-MS method for the detection of volatile nitrosamines in meat samples.

作者信息

Roasa Joy, Liu Huaizhi, Shao Suqin

机构信息

a Guelph Research and Development Centre, Agriculture and Agri-Food Canada , Guelph , ON , Canada.

出版信息

Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2019 Mar;36(3):396-404. doi: 10.1080/19440049.2019.1571287. Epub 2019 Feb 7.

Abstract

A method to detect volatile nitrosamines in meat samples was developed using headspace sampling by solid-phase microextraction (HS-SPME), with analysis by GC-MS. A 50/30 µm divinylbenzene/carboxen/polydimethylsiloxane fused silica fibre was selected to extract a total of nine volatile nitrosamines: N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosodi-n-propylamine, N-nitrosomorpholine, N-nitrosopyrrolidine, N-nitrosopiperidine, N-nitrosodi-n-butylamine, and N-nitrosodiphenylamine. Extraction at 65°C for 45 min with 36% (w/v) NaCl were the optimal conditions determined for the extraction of nine nitrosamines. Excellent linearity was obtained for all analytes with determination coefficients greater than 0.997. Recovery rates were between 92 and 113%. The relative standard deviation ranged from 0.81 to 8.0% for six of the nine compounds, and from 16 to 32% for the other three. For seven out of nine nitrosamines, limits of detection were below 3.6 µg kg and the limits of quantification were below 12 µg kg. The nitrosamine levels in four varieties of processed meat products were investigated to assess the applicability of the method. Based on the results, the developed HS-SPME-GC-MS method proved to be a simple and efficient technique to detect seven out of nine nitrosamines in meat products with adequate sensitivity, accuracy and precision.

摘要

建立了一种采用顶空固相微萃取(HS-SPME)结合气相色谱-质谱联用(GC-MS)分析肉类样品中挥发性亚硝胺的方法。选用50/30 µm二乙烯基苯/碳分子筛/聚二甲基硅氧烷熔融石英纤维萃取9种挥发性亚硝胺,分别为N-亚硝基二甲胺、N-亚硝基甲乙胺、N-亚硝基二乙胺、N-亚硝基二正丙胺、N-亚硝基吗啉、N-亚硝基吡咯烷、N-亚硝基哌啶、N-亚硝基二正丁胺和N-亚硝基二苯胺。确定最佳萃取条件为:在65℃下,使用36%(w/v)氯化钠萃取45分钟,用于萃取这9种亚硝胺。所有分析物均具有良好的线性,决定系数大于0.997。回收率在92%至113%之间。9种化合物中有6种的相对标准偏差在0.81%至8.0%之间,另外3种在16%至32%之间。9种亚硝胺中有7种的检测限低于3.6 µg/kg,定量限低于12 µg/kg。研究了4种加工肉类产品中的亚硝胺含量,以评估该方法的适用性。结果表明,所建立的HS-SPME-GC-MS方法是一种简单有效的技术,能够以足够的灵敏度、准确度和精密度检测肉类产品中9种亚硝胺中的7种。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验