Suppr超能文献

A novel diagnostic system for Doppler ultrasound of the peripheral arteries to detect the presence of thoracic aortic aneurysm.

作者信息

Hayatsu Yukihiro, Watanabe Koyu, Sasaki Konosuke, Masaki Naoki, Katahira Shintaro, Kumagai Kiichiro, Kawamoto Shunsuke, Ohmi Toshihito, Yokobori A Toshimitsu, Saiki Yoshikatsu

机构信息

Division of Cardiovascular Surgery, Graduate School of Medicine, Tohoku University, Sendai, Japan.

Department of Mechanical Engineering, Shonan Institute of Technology, Fujisawa, Japan.

出版信息

Biomed Mater Eng. 2019;30(2):231-241. doi: 10.3233/BME-191047.

Abstract

OBJECTIVE

We aimed to develop a novel ultrasound system and examine its feasibility for noninvasively detecting thoracic aortic aneurysm (TAA) in clinical settings.

METHODS

We developed a novel ultrasound system consisting of a modified console and data analysis algorithm. The exploratory study included 100 patients hospitalized for elective cardiovascular surgery. After admission, the arterial pulse waveform at the left carotid artery was acquired using the novel system. Based on these data, we inferred the presence of TAA based on arterial viscoelasticity and instability, which are reflected into the time-averaged trajectory of deformation of the blood vessel wall caused by disturbance of blood flow. Meanwhile, all patients underwent computed tomography as preoperative screening to confirm the presence of TAA. The sensitivity and specificity of TAA detection using the novel ultrasound system were calculated.

RESULTS

The datasets from 37 patients were not suitable for analysis and were thus discarded. Based on computed tomography findings, 40 patients were categorized into the aneurysm group while 23 were judged not to have and aortic aneurysm. On the other hand, 44 patients were diagnosed as having TAA based on ultrasound findings obtained using the novel system. The overall sensitivity and specificity of the ultrasound system were 0.83 and 0.52, respectively.

CONCLUSION

We successfully developed a novel system for noninvasive, ultrasound-based evaluation of the left carotid artery to detect TAA. Although improvements to the probe and diagnostic algorithm are warranted, this device has potential utility for mass screening to detect asymptomatic TAA as part of community-level healthcare programs.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验