Suppr超能文献

在混合髋关节置换术中,40毫米股骨头和第二代三次退火的HCLPE内衬在短期内失败率较低。

Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

作者信息

Thangaraj Rajkumar, Kuiper Jan, Perkins Ralph D

机构信息

Princess Royal Hospital, Telford, United Kingdom.

ISTM, Keele University, Keele, ST5 5BG, United Kingdom.

出版信息

J Clin Orthop Trauma. 2019 Mar-Apr;10(2):350-357. doi: 10.1016/j.jcot.2017.12.008. Epub 2018 Jan 3.

Abstract

INTRODUCTION

40 mm large diameter heads offer the advantages of lesser dislocation rates and better stability while highly cross linked polyethylene have lower wear rates than ultra high molecular weight polyethylene. Studies of the survivorship of 40 mm heads in hybrid hip replacements with Exeter stem and second generation highly cross linked polyethylene are limited. The purpose of the study is to report the short term of survivorship of the large diameter heads (40 mm) with Exeter stem with the secondary aim being the survival analysis of the thinnest second generation highly cross linked polyethylene.

METHODS

Retrospective case series of survivorship of patients with hybrid hip replacements of Exeter stems with 40 mm heads articulating with second generation triple annealed highly cross linked polyethylene liner on a uncemented acetabular shell was performed. As a subset, survival of thinnest second generation highly cross linked polyethylene survival (3.8 mm) at short term was assessed. Survival of the implants was confirmed from the hospital records and National joint registry as of 2015. Revision for any cause was taken as end point.

RESULTS

324 hybrid hip replacements with 40 mm heads had been performed for primary hip osteoarthritis. Of the 324 hip replacements, 154 hip replacements had thinnest second generation highly cross linked polyethylene (3.8 mm). Two patients had revision of components, one for periprosthetic fracture and one for deep infection. Mean age of the patients was 70.5 years (range 42-88 years, median 71, SD 8.3 years). None of the patients had revision due to trunion wear or loosening of components. The overall 5-year implant survival probability of hips with 40 mm heads was 99.4% (95% CI 98 to 100%) while the subset group of hip replacements with thinnest second generation highly cross linked polyethylene (3.8 mm) had 5-year implant survival probability of 99.3% (95% CI 97.1 to 100%).

CONCLUSION

Short term survivorship does not show significant evidence of early failure or higher rate of revision in our series of hybrid hip replacements with large diameter heads and second generation triple annealed highly cross linked polyethylene. Dislocation rate at the short term is none. Results from this series have to be carefully interpreted due to the relatively short follow up but so far results are encouraging. Long term follow up is required to conclude whether there is early or higher rate of failure. It is our intention to follow up this cohort and further publish our results at longer term.

摘要

引言

40毫米大直径股骨头具有脱位率较低和稳定性更好的优点,而高度交联聚乙烯的磨损率低于超高分子量聚乙烯。关于埃克塞特柄与第二代高度交联聚乙烯的混合髋关节置换术中40毫米股骨头生存率的研究有限。本研究的目的是报告埃克塞特柄大直径(40毫米)股骨头的短期生存率,次要目的是对最薄的第二代高度交联聚乙烯进行生存分析。

方法

对采用埃克塞特柄进行混合髋关节置换、40毫米股骨头与第二代三重退火高度交联聚乙烯内衬在非骨水泥髋臼壳上进行关节置换的患者进行回顾性病例系列生存研究。作为一个子集,评估了最薄的第二代高度交联聚乙烯(3.8毫米)在短期内的生存率。截至2015年,通过医院记录和国家关节登记处确认植入物的生存情况。将因任何原因进行翻修作为终点。

结果

共对324例原发性髋骨关节炎患者进行了40毫米股骨头的混合髋关节置换。在这324例髋关节置换中,154例使用了最薄的第二代高度交联聚乙烯(3.8毫米)。两名患者进行了假体翻修,一名因假体周围骨折,一名因深部感染。患者的平均年龄为70.5岁(范围42 - 88岁,中位数71岁,标准差8.3岁)。没有患者因耳轴磨损或假体松动而进行翻修。40毫米股骨头髋关节的总体5年植入物生存概率为99.4%(95%可信区间98%至100%),而使用最薄的第二代高度交联聚乙烯(3.8毫米)的髋关节置换子集组的5年植入物生存概率为99.3%(95%可信区间97.1%至100%)。

结论

在我们这组采用大直径股骨头和第二代三重退火高度交联聚乙烯的混合髋关节置换系列中,短期生存率未显示出早期失败或更高翻修率的显著证据。短期内脱位率为零。由于随访时间相对较短,本系列结果必须谨慎解读,但目前结果令人鼓舞。需要进行长期随访以确定是否存在早期或更高的失败率。我们打算对该队列进行随访,并在更长时间后进一步公布我们的结果。

相似文献

本文引用的文献

5
Trunnionosis in total hip arthroplasty: a review.全髋关节置换术中的股骨柄松动:综述
J Orthop Traumatol. 2016 Mar;17(1):1-6. doi: 10.1007/s10195-016-0391-1. Epub 2016 Feb 11.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验