Abstract

The TBI is performed with 8 MV X-rays of a linear accelerator. The procedure is divided into a lateral and a.p./p.a. segment with a weighting factor of 5/6 and 1/6 respectively. For the lateral segment no compensators are employed. Only the upper part of the arms are used to shield the lungs. In the a.p./p.a. segment two or three fields have to be used on account of the small FSD. Here head and neck are shielded depending on the overdosage in the lateral segment. The dose given to the lungs is limited by mantlefield-technique to 10.5 Gy. The total midline dose amounts to 12 Gy and is applicated on three days with two fractions per day.

摘要

全脑照射(TBI)使用直线加速器的8兆伏X射线进行。该程序分为侧野和前后野两个部分,权重因子分别为5/6和1/6。对于侧野部分,不使用补偿器。仅使用双臂的上部来屏蔽肺部。在前后野部分,由于焦皮距较小,必须使用两到三个照射野。在这里,根据侧野部分的过量照射情况对头部和颈部进行屏蔽。通过斗篷野技术将肺部的剂量限制在10.5戈瑞。总中线剂量为12戈瑞,分三天给予,每天两次。