Nilsson C G, Lahteenmaki P L, Luukkainen T, Robertson D N
Fertil Steril. 1986 Jun;45(6):805-7. doi: 10.1016/s0015-0282(16)49397-0.
Two models of levonorgestrel-releasing intrauterine devices were studied. Model A was designed to deliver 20 micrograms/day, and model B was designed to deliver 30 micrograms/day. Plasma concentrations of levonorgestrel were determined in blood samples taken from women who used the levonorgestrel-releasing intrauterine devices (IUDs) and who participated in a clinical trial for more than 5 years. During clinical studies IUDs have been removed for various reasons between 8 and 40 months after insertion. The rate of release of levonorgestrel from the IUDs was calculated by determining the remaining amount of levonorgestrel. Plasma concentrations of levonorgestrel ranged between a mean +/- standard deviation (SD) concentration of 166 +/- 75 pg/ml and 131 +/- 32 pg/ml for the first 18 months of use and between 101 +/- 37 pg/ml and 74 +/- 15 pg/ml at 24 and 60 months after insertion of the IUD. The plasma concentrations from 24 months through 60 months were significantly lower than concentrations measured during initial months of IUD use, but not between the two devices. There was a strong correlation between the time of use and the amount of levonorgestrel lost from the IUDs. The calculated mean daily release of levonorgestrel was 17.6 micrograms for model A and 22.2 micrograms for model B. This gives a calculated lifetime of more than 6 years for a levonorgestrel-releasing IUD.
对两种左炔诺孕酮宫内节育器模型进行了研究。A 型设计为每日释放 20 微克,B 型设计为每日释放 30 微克。对使用左炔诺孕酮宫内节育器(IUD)且参与一项超过 5 年的临床试验的女性采集血样,测定其中左炔诺孕酮的血浆浓度。在临床研究期间,IUD 在插入后 8 至 40 个月因各种原因被取出。通过测定左炔诺孕酮的剩余量来计算其从 IUD 中的释放速率。在使用的前 18 个月,左炔诺孕酮的血浆浓度范围为平均±标准差(SD)浓度 166±75 皮克/毫升至 131±32 皮克/毫升,在插入 IUD 后 24 个月和 60 个月时,浓度范围为 101±37 皮克/毫升至 74±15 皮克/毫升。从 24 个月到 60 个月的血浆浓度显著低于 IUD 使用最初几个月测得的浓度,但两种装置之间无差异。使用时间与左炔诺孕酮从 IUD 中损失的量之间存在很强的相关性。计算得出 A 型左炔诺孕酮的平均每日释放量为 17.6 微克,B 型为 22.2 微克。这表明左炔诺孕酮宫内节育器的计算使用寿命超过 6 年。