Valls Sanchez F, Puig J, Olivares G, Holloway A, Seth M
Department of Small Animal Internal Medicine, Animal Health Trust, Newmarket, Suffolk, CB8 7UU, UK.
Department of Radiology, Animal Health Trust, Newmarket, Suffolk, CB8 7UU, UK.
J Small Anim Pract. 2019 Jun;60(6):361-366. doi: 10.1111/jsap.12996. Epub 2019 Mar 13.
To evaluate association between ultrasonographic urine echogenicity and sediment examination in dogs and cats.
Dogs and cats undergoing ultrasound-guided cystocentesis at a multidisciplinary referral hospital. Ultrasonographic images were stored and reviewed by a single, blinded, board-certified radiologist. Urine appearance was described as "echoic" or "anechoic". Urine sediment was examined for bacteriuria, pyuria, haematuria, crystalluria and urine-specific gravity and then classified as "active" or "inactive."
Of the 194 cases included in this study, urine was echoic in 52 and anechoic in 142. Sediment was active in 52 and inactive in 142 samples. Sensitivity and specificity of echoic urine for active sediment were 40% (95% CI: 27 to 55%) and 78% (95% CI: 70 to 85%), respectively. Positive predictive value and negative predictive value of echoic urine for active sediment were 40% (CI 30 to 52%) and 78% (CI 74 to 82%), respectively. If urine-specific gravity was <1.015 urine was always described ultrasonographically as anechoic.
Association between sediment analysis and ultrasonographic appearance of urine is poor. Echoic urine had low positive predictive value for active sediment in this study, suggesting that echoic urine alone should not prompt urinary investigations in the absence of other clinical suspicion. Despite a negative predictive value of 78%, urinalysis is still indicated for anechoic urine, especially if urine specific gravity is low.
评估犬猫超声检查尿液回声性与沉渣检查之间的相关性。
在一家多学科转诊医院接受超声引导下膀胱穿刺术的犬猫。超声图像由一名经过认证的、盲法操作的放射科医生存储并审查。尿液外观被描述为“有回声”或“无回声”。对尿沉渣进行细菌尿、脓尿、血尿、结晶尿和尿比重检查,然后分为“活跃”或“不活跃”。
本研究纳入的194例病例中,52例尿液有回声,142例无回声。52例沉渣活跃,142例不活跃。有回声尿液对活跃沉渣的敏感性和特异性分别为40%(95%CI:27至55%)和78%(95%CI:70至85%)。有回声尿液对活跃沉渣的阳性预测值和阴性预测值分别为40%(CI 30至52%)和78%(CI 74至82%)。如果尿比重<1.015,超声检查尿液总是被描述为无回声。
沉渣分析与尿液超声表现之间的相关性较差。在本研究中,有回声尿液对活跃沉渣具有较低的阳性预测值,这表明在没有其他临床怀疑的情况下,仅尿液有回声不应促使进行尿液检查。尽管阴性预测值为78%,但对于无回声尿液仍需进行尿液分析,尤其是当尿比重较低时。