Suppr超能文献

健康志愿者经皮高频和低频脊髓刺激后比目鱼肌H反射调制

Soleus H-reflex modulation following transcutaneous high- and low-frequency spinal stimulation in healthy volunteers.

作者信息

Serrano-Muñoz Diego, Gómez-Soriano Julio, Bravo-Esteban Elisabeth, Ávila-Martín Gerardo, Galán-Arriero Iriana, Taylor Julian, Avendaño-Coy Juan

机构信息

Sensorimotor Function Group, Hospital Nacional de Parapléjicos, Toledo 45071, Spain.

Toledo Physiotherapy Research Group (GIFTO), Nursing and Physiotherapy School, Castilla La Mancha University, Toledo 45071, Spain.

出版信息

J Electromyogr Kinesiol. 2019 Jun;46:1-7. doi: 10.1016/j.jelekin.2019.03.004. Epub 2019 Mar 7.

Abstract

The main aim of this work was to investigate the difference in the excitability of the soleus H-reflex in healthy volunteers following spinal transcutaneous electrical nerve stimulation (TENS) and high-frequency alternating current (HFAC) at a frequency of 10 kHz applied at the lower thoracic spinal level (T10-T12). A double-blind, randomized, crossover, controlled clinical trial was designed. Participants received three randomized interventions (TENS, 10 kHz, and sham stimulation) during 40 min. The amplitude and latency of the soleus H-reflex were registered prior to, during, and 10 min following stimulation. Twenty-four participants completed the study. A significant inhibition of H-reflex amplitude was observed following transcutaneous spinal TENS (12.7%; 95% CI 1.5-22.2%) when compared with sham stimulation (5.5%; 95% CI 3.6-14.5%; p = 0.03). An increase in H-reflex latency was also observed following transcutaneous spinal stimulation at 10 kHz (2%; 95% CI 1.4-2.5%) as compared with sham stimulation (0.7%; 95% CI 0.07-1.3%; p < 0.01). No differences were found between TENS and 10 kHz for H-reflex modulation. Transcutaneous spinal TENS and HFAC at a frequency of 10 kHz had a modulatory effect on the soleus H-reflex when compared to sham stimulation; however, no differences were found between these two interventions.

摘要

这项工作的主要目的是研究在健康志愿者中,于下胸段脊髓水平(T10 - T12)施加脊髓经皮电刺激(TENS)和10千赫高频交流电(HFAC)后比目鱼肌H反射兴奋性的差异。设计了一项双盲、随机、交叉、对照临床试验。参与者在40分钟内接受三种随机干预(TENS、10千赫和假刺激)。在刺激前、刺激期间和刺激后10分钟记录比目鱼肌H反射的幅度和潜伏期。24名参与者完成了研究。与假刺激(5.5%;95%置信区间3.6 - 14.5%;p = 0.03)相比,经皮脊髓TENS后观察到H反射幅度有显著抑制(12.7%;95%置信区间1.5 - 22.2%)。与假刺激(0.7%;95%置信区间0.07 - 1.3%;p < 0.01)相比,在10千赫经皮脊髓刺激后也观察到H反射潜伏期增加(2%;95%置信区间1.4 - 2.5%)。在H反射调制方面,TENS和10千赫之间未发现差异。与假刺激相比,经皮脊髓TENS和10千赫的HFAC对比目鱼肌H反射有调制作用;然而,这两种干预之间未发现差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验