Suppr超能文献

[采用多孔涂层干骺端套筒和MBT植入物的翻修全膝关节置换术的短期疗效]

[Short-term effectiveness of revision total knee arthroplasty with porous-coated metaphyseal Sleeve and MBT implant].

作者信息

Guo Lingfei, Du Yinqiao, Zhang Mingchao, Sun Jingyang, Jin Zhigang, Peng Yawen, Shen Junmin, Zhou Yonggang

机构信息

Department of Orthopedics, General Hospital of Chinese PLA, Beijing, 100853, P.R.China;Department of Orthopedics, the 316th Military Hospital of China, Beijing, 100093, P.R.China.

Department of Orthopedics, General Hospital of Chinese PLA, Beijing, 100853, P.R.China.

出版信息

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2019 Mar 15;33(3):302-306. doi: 10.7507/1002-1892.201810026.

Abstract

OBJECTIVE

To evaluate short-term effectiveness of revision total knee arthroplasty (TKA) with porous-coated metaphyseal Sleeve and MBT implant.

METHODS

A clinical data of 23 patients (24 knees) who underwent revision TKA by using porous-coated metaphyseal Sleeve combined with MBT implant between March 2015 and April 2017 was retrospectively analyzed. There were 8 males (8 knees) and 15 females (16 knees). The age ranged from 48 to 85 years (mean, 65.4 years). The cause of revision TKA included infection in 14 knees, aseptic loosening in 8 knees, instability in 1 knee, and stiff knee in 1 knee. Bone defects were classified according to the Anderson Orthopaedic Research Institute (AORI) bone defect classification. The femoral defect was rated as type ⅡA in 5 knees, type ⅡB in 17 knees, and type Ⅲ in 2 knees; the tibial defect was rated as type ⅡA in 2 knees, type ⅡB in 20 knees, and type Ⅲ in 2 knees. The mean time between primary TKA and revision TKA was 30.6 months (range, 6-86 months). The preoperative range of motion (ROM) was (56.0±24.9)°. The preoperative Hospital for Special Surgery (HSS) total score was 41.9±14.2; and the pain and function scores were 8.5±5.2 and 33.4±13.5, respectively.

RESULTS

All patients were followed up 12-39 months (mean, 25.6 months). The mean operation time was 2.2 hours (range, 1.6-2.9 hours). The mean intraoperative blood loss was 580 mL (range, 400-1 000 mL). There were 2 knees (8.3%) of intraoperative fracture associated with Sleeve insertion and 1 knee (4.2%) of acute postoperative infection at 25 days after revision TKA. All incisions healed by first intention. No deep venous thrombosis of lower extremity occurred. X-ray film showed that all implants were stable. At last follow-up, slight discomfort after exercise occurred in 4 knees (16.7%); end-of-stem pain in the tibia occurred in 1 knee (4.2%). The ROM was (114.6±5.1)°, which had significant improvement compared with the preoperative result ( =11.698, =0.000). The HSS total score (89.0±10.9), pain score (26.9±6.6), and function score (62.1±5.8) also had significant improvement compared with the preoperative results ( =15.616, =0.000; =12.522, =0.000; =10.076, =0.000).

CONCLUSION

The porous-coated metaphyseal Sleeve combined with MBT implant in revision TKA has a significant improvement in short-term effectiveness and no signs of implant loosening.

摘要

目的

评估采用多孔涂层干骺端套筒和MBT植入物进行翻修全膝关节置换术(TKA)的短期疗效。

方法

回顾性分析2015年3月至2017年4月期间采用多孔涂层干骺端套筒联合MBT植入物进行翻修TKA的23例患者(24膝)的临床资料。其中男性8例(8膝),女性15例(16膝)。年龄48至85岁(平均65.4岁)。翻修TKA的原因包括14膝感染、8膝无菌性松动、1膝不稳定和1膝膝关节僵硬。根据安德森矫形研究所(AORI)骨缺损分类对骨缺损进行分类。股骨缺损5膝评为ⅡA型,17膝评为ⅡB型,2膝评为Ⅲ型;胫骨缺损2膝评为ⅡA型,20膝评为ⅡB型,2膝评为Ⅲ型。初次TKA与翻修TKA之间的平均时间为30.6个月(范围6 - 86个月)。术前活动范围(ROM)为(56.0±24.9)°。术前特种外科医院(HSS)总分41.9±14.2;疼痛和功能评分分别为8.5±5.2和33.4±13.5。

结果

所有患者均获随访12 - 39个月(平均25.6个月)。平均手术时间为2.2小时(范围1.6 - 2.9小时)。平均术中失血量为580 mL(范围400 - 1000 mL)。有2膝(8.3%)在套筒插入时发生术中骨折,1膝(4.2%)在翻修TKA术后25天发生急性感染。所有切口均一期愈合。未发生下肢深静脉血栓形成。X线片显示所有植入物均稳定。末次随访时,4膝(16.7%)运动后出现轻微不适;1膝(4.2%)胫骨柄末端疼痛。ROM为(114.6±5.1)°,与术前结果相比有显著改善(=11.698,=0.000)。HSS总分(89.0±10.9)、疼痛评分(26.9±6.6)和功能评分(62.1±5.8)与术前结果相比也有显著改善(=15.616,=0.000;=12.522,=0.000;=10.076,=0.000)。

结论

多孔涂层干骺端套筒联合MBT植入物用于翻修TKA的短期疗效有显著改善,且无植入物松动迹象。

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验