Cooper Bone and Joint Institute, Camden, NJ, USA.
Rothman Institute, Thomas Jefferson University Hospital, Philadelphia, PA, USA.
Knee Surg Sports Traumatol Arthrosc. 2018 May;26(5):1500-1505. doi: 10.1007/s00167-017-4493-y. Epub 2017 Mar 17.
Porous-coated metaphyseal sleeves are designed to fill bone defects and facilitate osseointegration when bone loss in encountered during revision total knee arthroplasty (TKA). The purpose of this study is to evaluate short-term results of porous-coated metaphyseal sleeves with regards to implant fixation and clinical outcomes.
A retrospective review was conducted on 50 patients (79 sleeves-49 tibial and 30 femoral) who had a press-fit metaphyseal sleeve with revision TKA. Tibial and femoral bone loss was classified according to the Anderson Orthopaedic Research Institute (AORI) bone defect classification. Post-operative complications of infection, revision surgery, and dislocation were assessed. Follow-up radiographs were evaluated for signs of loosening using the criteria developed by the Knee Society. The median follow-up was 58.8 months (range 25.8-93.0 months).
The bone loss classifications were 1 type 1, 30 type 2a, 2 type 2b, and 17 type 3, and with regards to the femur, 5 were type 1, 8 type 2a, 31 type 2b, and 6 type 3. At final follow-up, 41/45 (91.1%) tibial and 28/29 (96.6%) femoral sleeves showed radiographic evidence of ingrowth. Of these 69 patients, all showed radiographic evidence of bony ingrowth. Three sleeves were revised for infection and two for loosening. The re-operation rate for loosening was 5/74 (6.8%) and for any reason was 14/74 (18.9%).
Modular porous-coated press fit metaphyseal sleeves fill defects and provide evidence of radiographic ingrowth. Short-term stable fixation can be achieved with sleeves, which is helpful as more patients undergo revision total knee arthroplasty with greater bone loss. Longer duration studies are needed to ascertain the survival rate of these implants.
IV.
多孔涂层干骺端袖套旨在填补骨缺损,并在翻修全膝关节置换术 (TKA) 中遇到骨丢失时促进骨整合。本研究旨在评估多孔涂层干骺端袖套在植入物固定和临床结果方面的短期结果。
对 50 例(79 个袖套 - 49 个胫骨和 30 个股骨)接受加压配合干骺端袖套翻修 TKA 的患者进行回顾性研究。根据安德森骨科研究所 (AORI) 骨缺损分类对胫骨和股骨骨丢失进行分类。评估感染、翻修手术和脱位等术后并发症。使用膝关节协会制定的标准评估随访 X 线片有无松动迹象。中位随访时间为 58.8 个月(范围 25.8-93.0 个月)。
骨丢失分类为 1 型 1 例,30 型 2a 例,2 型 2b 例,17 型 3 例,股骨 5 型 1 例,8 型 2a 例,31 型 2b 例,6 型 3 例。最终随访时,41/45(91.1%)胫骨和 28/29(96.6%)股骨袖套均有影像学证据显示骨内生长。在这 69 名患者中,所有患者均有影像学证据显示骨内生长。3 个袖套因感染而翻修,2 个因松动而翻修。因松动而再次手术的发生率为 5/74(6.8%),因任何原因而再次手术的发生率为 14/74(18.9%)。
模块化多孔涂层压配合干骺端袖套可填补缺损并提供影像学骨内生长的证据。袖套可实现短期稳定固定,这对于更多接受翻修全膝关节置换术且骨丢失更大的患者是有帮助的。需要进行更长时间的研究来确定这些植入物的存活率。
IV。