Hughes Dawn S, Whittington Julie R, Kim Hyein, Gunderman Brianna, Ounpraseuth Songthip, Magann Everett F
Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, AR.
Department of Obstetrics and Gynecology, Seoul National University College of Medicine, Seoul, South Korea.
J Obstet Gynaecol Can. 2019 Sep;41(9):1295-1301. doi: 10.1016/j.jogc.2019.01.017. Epub 2019 Mar 23.
This study sought to determine whether there is a significant difference in amniotic fluid measurements when measuring perpendicular to the floor compared with perpendicular to the uterine contour using both amniotic fluid index and single deepest pocket.
This was a single-centre, prospective study of women with singleton gestation who were undergoing fetal ultrasound examination. A total of 240 women were enrolled, and single deepest pocket and amniotic fluid index were measured with both techniques. Correlation coefficient and intraclass correlation coefficient were used to assess the agreement between the values using the two methods of measurement (Canadian Task Force Classification II-2).
A strong correlation was found between amniotic fluid index measurements (correlation coefficient 0.82; intraclass correlation coefficient 0.7). A strong correlation also was found between single deepest pocket measurements (correlation coefficient 0.7; intraclass correlation coefficient 0.6).
The measurement of amniotic fluid index and single deepest pocket can be performed either perpendicular to the floor or perpendicular to the uterine contour. There is no significant difference between these measurements and they correlate well.
本研究旨在确定使用羊水指数和单个最深羊水池时,与垂直于子宫轮廓测量相比,垂直于地面测量羊水时是否存在显著差异。
这是一项针对单胎妊娠且正在接受胎儿超声检查的女性的单中心前瞻性研究。共纳入240名女性,使用两种技术测量单个最深羊水池和羊水指数。相关系数和组内相关系数用于评估两种测量方法所得值之间的一致性(加拿大工作组分类II - 2)。
羊水指数测量之间发现强相关性(相关系数0.82;组内相关系数0.7)。单个最深羊水池测量之间也发现强相关性(相关系数0.7;组内相关系数0.6)。
羊水指数和单个最深羊水池的测量既可以垂直于地面进行,也可以垂直于子宫轮廓进行。这些测量之间无显著差异且相关性良好。