Suppr超能文献

多种变量对白内障手术后屈光不正的影响。

EFFECT OF MULTIPLE VARIABLES ON THE REFRACTIVE ERROR AFTER CATARACT SURGERY.

作者信息

Popov I, Valašková J, Krásnik V, Tomčíková D

出版信息

Cesk Slov Oftalmol. 2019 Winter;74(4):158-161. doi: 10.31348/2018/1/4-6-2018.

Abstract

PURPOSE

To analyze refractive results after cataract surgery in relation to used type of monofocal intraocular lens, calculation formula, to age, gender and laterality.

SETTINGS

Department of Ophthalmology, Comenius University and University hospital in Bratislava, Slovakia Methods: We analyzed 173 eyes (118 patients) after uneventful cataract surgery. We calculated prediction error (PE) and mean absolute error (MAE) of postoperative refraction.

RESULTS AND CONCLUSION

We found no statistically significant differences in PE and MAE in relation to types of used IOL, calculation formulas, gender, age or laterality. Key words: Optical biometry, monofocal IOL, IOL calculation, refractive error.

摘要

目的

分析白内障手术后的屈光结果与所使用的单焦点人工晶状体类型、计算公式、年龄、性别及眼别之间的关系。

机构

斯洛伐克布拉迪斯拉发夸美纽斯大学和大学医院眼科

方法

我们分析了118例患者行白内障手术顺利的173只眼。我们计算了术后屈光的预测误差(PE)和平均绝对误差(MAE)。

结果与结论

我们发现,在预测误差和平均绝对误差方面,所使用的人工晶状体类型、计算公式、性别、年龄或眼别之间无统计学显著差异。

关键词

光学生物测量、单焦点人工晶状体、人工晶状体计算、屈光不正