Suppr超能文献

一种新型便携式系绳冲刺跑测试作为最大无氧能力测量指标的可靠性和有效性。

Reliability and Validity of a New Portable Tethered Sprint Running Test as a Measure of Maximal Anaerobic Performance.

机构信息

Department of Sports Medicine and Sports Nutrition, Ruhr-University Bochum, Bochum, Germany; and.

Institute of Outdoor Sports and Environmental Science, German Sports University Cologne, Cologne, Germany.

出版信息

J Strength Cond Res. 2020 Aug;34(8):2197-2204. doi: 10.1519/JSC.0000000000003119.

Abstract

Limmer, M, Berkholz, A, de Marées, M, and Platen, P. Reliability and validity of a new portable tethered sprint running test as a measure of maximal anaerobic performance. J Strength Cond Res 34(8): 2197-2204, 2020-The purposes of this study were to develop a new portable tethered sprint running (PTSR) test for field-based anaerobic performance testing with restricted spatial conditions and the logistical challenge of carrying test equipment, and to determine reliability of the PTSR test. For validity, performance measures were compared with the cycle ergometer Wingate Anaerobic Test (WAnT) power outputs. Twelve recreationally active men and women (24.3 ± 1.6 years; 1.77 ± 0.07 m; 73.3 ± 12.5 kg) performed one familiarization trial followed by 3 randomly assigned experimental 60-second all-out effort trials consisting of one WAnT and 2 PTSR tests. All trials were performed in a randomized order on different days separated by at least 48 hours. Heart rate (HR) and maximum blood lactate concentration were recorded for each experimental trial to determine the physiological responses to the maximal efforts. Correlation coefficients indicated significant relationships between mean force (MF) and peak force (PF) in the PTSR test and mean power (MP) (r = 0.651, p = 0.022) and peak power (PP) (r = 0.877, p = 0.002) in the WAnT, but not for the fatigue index (r = 0.280, p = 0.379). In addition, both PTSR trials showed no significant differences (p > 0.05) between trials and a high reliability for the performance variables MF (intraclass correlation coefficient [ICC] = 0.98, coefficient of variation [%CV] = 7.7), PF (ICC = 0.98, %CV = 8.4), and HR (ICC = 0.92, %CV = 3.1). In conclusion, our results suggest that despite insufficient stimulation of anaerobic metabolism in some subjects resulting from poor implementation of test instructions, the PTSR is a reliable and valid test for an easy and practical assessment of maximal anaerobic performance under different field conditions.

摘要

利默、伯克霍兹、德马雷、普拉丁。一种新的便携式系绳冲刺跑测试作为最大无氧性能测量手段的可靠性和有效性。J 力量与调节研究 34(8):2197-2204,2020-本研究的目的是开发一种新的便携式系绳冲刺跑(PTSR)测试,用于在空间条件受限和携带测试设备的后勤挑战的情况下进行现场无氧性能测试,并确定 PTSR 测试的可靠性。为了验证有效性,将性能测量与测功计无氧测试(WAnT)的功率输出进行比较。12 名有经验的男性和女性(24.3±1.6 岁;1.77±0.07 m;73.3±12.5 kg)进行了一次熟悉试验,然后进行了 3 次随机分配的 60 秒全力试验,包括一次 WAnT 和 2 次 PTSR 试验。所有试验均在不同的日子以随机顺序进行,间隔至少 48 小时。记录每个实验性试验的心率(HR)和最大血乳酸浓度,以确定最大努力的生理反应。相关系数表明,PTSR 测试中的平均力(MF)和峰值力(PF)与 WAnT 中的平均功率(MP)(r=0.651,p=0.022)和峰值功率(PP)(r=0.877,p=0.002)之间存在显著关系,但疲劳指数(r=0.280,p=0.379)之间没有关系。此外,两次 PTSR 试验之间没有显著差异(p>0.05),并且 MF(组内相关系数[ICC]=0.98,变异系数[%CV]=7.7)、PF(ICC=0.98,%CV=8.4)和 HR(ICC=0.92,%CV=3.1)等性能变量具有很高的可靠性。总之,尽管由于测试指令执行不当,导致一些受试者的无氧代谢刺激不足,但 PTSR 是一种可靠且有效的测试方法,可在不同的现场条件下轻松、实用地评估最大无氧性能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验