Park Jaehyeon, Yea Ji Woon
Department of Radiation Oncology, Yeungnam University College of Medicine, Daegu, Korea.
Radiat Oncol J. 2019 Mar;37(1):22-29. doi: 10.3857/roj.2019.00059. Epub 2019 Mar 31.
The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT).
Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity.
The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram.
Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.
本研究旨在通过比较双侧全脑放疗(B-WBRT)来评估使用倾斜底板的四野盒式全脑放疗(FB-WBRT)的疗效和可行性。
2016年3月至2018年9月期间,20例脑转移患者采用四野盒式技术接受全脑放疗。全脑放疗每日10次分割,剂量为30 Gy。每人进行两次计算机断层扫描模拟。一次是传统仰卧位用于B-WBRT,另一次是应用倾斜的丙烯酸仰卧底板将头部抬高40°用于FB-WBRT。B-WBRT采用野中野技术,这是我们机构最常用的方法。FB-WBRT包括前、后和双侧射野。在前、后野应用楔形板以补偿颅骨凸度。
B-WBRT中双侧腮腺的平均Dmean为10.2 Gy(范围3.8至17.8 Gy),FB-WBRT中为5.4 Gy(范围2.0至11.7 Gy)(p < 0.05)。与B-WBRT相比,FB-WBRT将右侧和左侧腮腺的平均剂量分别从10.1 Gy降至4.9 Gy和从10.4 Gy降至5.8 Gy(p < 0.05)。此外,FB-WBRT中腮腺的V5、V10、V15、V20和V25显著降低(p < 0.05)。根据剂量体积直方图,晶状体的Dmax和Dmean降低。
与B-WBRT相比,使用倾斜底板的FB-WBRT是一种简单有效的方法,利用非共面射野的特点来保护腮腺。