Abstract

In cases where cemented components are used in total hip arthroplasty, damage, or disruption of the cement mantle can lead to aseptic loosening and joint failure. Currently, the relationship between subject activity level, obesity, and prosthetic femoral head size and the risk of aseptic loosening of the acetabular component in cemented total hip arthroplasty is not well understood. This study aims to provide an insight into this. Finite element models, validated with experimental data, were developed to investigate stresses in the acetabular cement mantle and pelvic bone resulting from the use of three prosthetic femoral head sizes, during a variety of daily activities and one high impact activity (stumbling) for a range of subject body weights. We found that stresses in the superior quadrants of the cortical bone-cement interface increased with prosthetic head size, patient weight, and activity level. In stumbling, average von Mises stresses (22.4 MPa) exceeded the bone cement yield strength for an obese subject (143 kg) indicating that the cement mantle would fail. Our results support the view that obesity and activity level are potential risk factors for aseptic loosening of the acetabular component and provide insight into the increased risk of joint failure associated with larger prosthetic femoral heads. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1771-1783, 2019.

摘要

在全髋关节置换术中使用粘结组件的情况下,粘结剂覆盖层的损坏或破裂可能导致无菌性松动和关节失效。目前,人们对患者活动水平、肥胖以及假体股骨头大小与粘结型全髋关节置换术后髋臼组件无菌性松动风险之间的关系了解甚少。本研究旨在对此进行深入探讨。我们使用实验数据验证了有限元模型,以研究在各种日常活动和一种高影响活动(绊倒)中,三种假体股骨头尺寸对髋臼粘结剂覆盖层和骨盆骨的应力的影响,以及不同患者体重的影响。我们发现,皮质骨-粘结剂界面的上象限的骨内应力随假体头尺寸、患者体重和活动水平的增加而增加。在绊倒时,肥胖患者(143kg)的平均 von Mises 应力(22.4MPa)超过了骨水泥屈服强度,表明粘结剂覆盖层将失效。我们的结果支持这样一种观点,即肥胖和活动水平是髋臼组件无菌性松动的潜在危险因素,并深入了解了与较大假体股骨头相关的关节失效风险增加的原因。©2019 矫形研究学会。由 Wiley Periodicals, Inc. 出版。J Orthop Res 37:1771-1783, 2019.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验