FIND, Geneva, Switzerland.
Meso Scale Diagnostics, LLC., Rockville, Maryland, United States of America.
PLoS One. 2019 Apr 18;14(4):e0215443. doi: 10.1371/journal.pone.0215443. eCollection 2019.
Tuberculosis (TB) infection was responsible for an estimated 1.3 million deaths in 2017. Better diagnostic tools are urgently needed. We sought to determine whether accurate TB antigen detection in blood or urine has the potential to meet the WHO target product profiles for detection of active TB.
We developed Electrochemiluminescence (ECL) immunoassays for Lipoarabinomannan (LAM) and ESAT-6 detection with detection limits in the pg/ml range and used them to compare the concentrations of the two antigens in the urine and serum of 81 HIV-negative and -positive individuals with presumptive TB enrolled across diverse geographic sites.
LAM and ESAT-6 overall sensitivities in urine were 93% and 65% respectively. LAM and ESAT-6 overall sensitivities in serum were 55% and 46% respectively. Overall specificity was ≥97% in all assays. Sensitivities were higher in HIV-positive compared to HIV-negative patients for both antigens and both sample types, with signals roughly 10-fold higher on average in urine than in serum. The two antigens showed similar concentration ranges within the same sample type and correlated.
LAM and ESAT-6 can be detected in the urine and serum of TB patients, regardless of the HIV status and further gains in clinical sensitivity may be achievable through assay and reagent optimization. Accuracy in urine was higher with current methods and has the potential to meet the WHO accuracy target if the findings can be transferred to a point-of-care TB test.
2017 年,结核病(TB)感染估计导致 130 万人死亡。迫切需要更好的诊断工具。我们旨在确定血液或尿液中准确的 TB 抗原检测是否有可能达到世界卫生组织(WHO)对检测活动性 TB 的目标产品特性的要求。
我们开发了用于脂阿拉伯甘露聚糖(LAM)和 ESAT-6 检测的电化学发光(ECL)免疫测定法,检测限在 pg/ml 范围内,并将其用于比较 81 名在不同地理地点就诊的疑似结核病的 HIV 阴性和阳性个体的尿液和血清中两种抗原的浓度。
尿液中 LAM 和 ESAT-6 的总体灵敏度分别为 93%和 65%。血清中 LAM 和 ESAT-6 的总体灵敏度分别为 55%和 46%。所有检测的总体特异性均≥97%。与 HIV 阴性患者相比,HIV 阳性患者的两种抗原和两种样本类型的灵敏度均较高,尿液中的信号平均高出 10 倍左右。同一样本类型中两种抗原的浓度范围相似且相关。
LAM 和 ESAT-6 可在 TB 患者的尿液和血清中检测到,无论 HIV 状态如何,通过检测和试剂优化,临床灵敏度可能进一步提高。目前的方法在尿液中的准确性更高,如果研究结果可以转化为即时检测 TB 测试,则有可能达到世卫组织的准确性目标。