Suppr超能文献

在接受解剖型全肩关节置换术的患者中,PROMIS 物理功能表现逊于美国肩肘外科医师评分的心理测量学表现。

PROMIS physical function underperforms psychometrically relative to American Shoulder and Elbow Surgeons score in patients undergoing anatomic total shoulder arthroplasty.

机构信息

Sports Medicine and Shoulder Service, Hospital for Special Surgery, New York, NY, USA.

Sports Medicine and Shoulder Service, Hospital for Special Surgery, New York, NY, USA.

出版信息

J Shoulder Elbow Surg. 2019 Sep;28(9):1809-1815. doi: 10.1016/j.jse.2019.02.011. Epub 2019 Apr 19.

Abstract

BACKGROUND

The purpose of this study was to evaluate the psychometric properties of the Patient-Reported Outcomes Measurement Information System (PROMIS) physical function computer adaptive test (PF-CAT) relative to the American Shoulder and Elbow Surgeons (ASES) score in patients with glenohumeral osteoarthritis undergoing primary anatomic total shoulder arthroplasty (TSA).

METHODS

A retrospective study of an institutional TSA registry was performed. Preoperative PROMIS PF-CAT and ASES scores were collected. Floor and ceiling effects were determined, and convergent validity was established through Pearson correlations. Rasch partial credit modeling was used for psychometric analysis of the validity of PF-CAT and ASES question items. Person-item maps were generated to characterize the distribution of question responses along the latent dimension of shoulder disability.

RESULTS

Responses from 179 patients (184 shoulders) were included. PF-CAT had a moderate correlation to ASES (r = 0.487; P < .001), with no floor or ceiling effects; ASES had a 1.1% floor effect and no ceiling effect. With iterative Rasch model item-reduction analysis eliminating poorly fitting question items, all possible PF-CAT items were eliminated after 6 iterations. With ASES, just 1 function question item was dropped. Person-item maps showed ASES to be superior to PROMIS PF-CAT psychometrically, with sequential and improved coverage of the latent dimension of shoulder disability.

CONCLUSION

Despite moderate correlation with ASES, PROMIS PF-CAT demonstrated inferior validity and psychometric properties in patients undergoing TSA. PF-CAT should not replace the ASES in this population of patients.

摘要

背景

本研究旨在评估患者报告结局测量信息系统(PROMIS)物理功能计算机自适应测试(PF-CAT)与美国肩肘外科医师协会(ASES)评分在接受初次解剖全肩关节置换术(TSA)的肩关节炎患者中的心理测量特性。

方法

对机构 TSA 注册处进行回顾性研究。收集术前 PROMIS PF-CAT 和 ASES 评分。确定地板和天花板效应,并通过 Pearson 相关建立收敛有效性。Rasch 部分信用模型用于 PF-CAT 和 ASES 问题项目有效性的心理测量分析。生成人员-项目图,以表征沿肩部残疾潜在维度的问题响应分布。

结果

纳入了 179 名患者(184 个肩膀)的反应。PF-CAT 与 ASES 中度相关(r = 0.487;P <.001),无地板或天花板效应;ASES 有 1.1%的地板效应,无天花板效应。通过迭代 Rasch 模型项目删减分析消除拟合不良的问题项目,在 6 次迭代后,所有可能的 PF-CAT 项目都被消除。对于 ASES,只有 1 个功能问题项目被删除。人员-项目图显示,ASES 在心理测量上优于 PROMIS PF-CAT,具有顺序和改进的肩部残疾潜在维度覆盖范围。

结论

尽管与 ASES 具有中度相关性,但在接受 TSA 的患者中,PROMIS PF-CAT 的有效性和心理测量特性较差。PF-CAT 不应替代该患者人群中的 ASES。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验