Ahn J H, Rosenfield R E, Kochwa S
Transfusion. 1987 Mar-Apr;27(2):125-33. doi: 10.1046/j.1537-2995.1987.27287150182.x.
Seven serologic procedures were studied to determine their respective value in compatibility and screening tests. All seven were significantly improved by the use of 4 volumes of serum, rather than 1, with 1 volume of red cell suspension, and a low-ionic antiglobin test (LIAGT) was distinctly superior to the other six procedures evaluated. In this test, during the incubation of serum and cells at 37 degrees for 20 minutes, ionic concentration was reduced 62 percent. However, after removal of all supernatant, the red cells were washed three times with an isotonic solution that provided 80 percent reduction in ionic concentration, and the washed cells were tested for their agglutinability with low-ionic (80% ionic reduction) anti-IgG antiglobin reagent. This modified LIAGT was usually more, and apparently never less, sensitive than a test described earlier and is expected to be associated with much less nonspecificity. The extreme sensitivity of LIAGT for many long-term frozen stored alloantiserums is a retained property of the modified test and has been associated with IgG aggregation during storage.
研究了七种血清学方法,以确定它们在相容性和筛查试验中的各自价值。通过使用4体积的血清而非1体积血清与1体积红细胞悬液,所有七种方法都有显著改进,并且低离子抗球蛋白试验(LIAGT)明显优于所评估的其他六种方法。在该试验中,血清和细胞在37℃孵育20分钟期间,离子浓度降低了62%。然而,去除所有上清液后,用等渗溶液将红细胞洗涤三次,该等渗溶液可使离子浓度降低80%,然后用低离子(离子浓度降低80%)抗IgG抗球蛋白试剂检测洗涤后的细胞的凝集性。这种改良的LIAGT通常比之前描述的试验更敏感,显然从不更不敏感,并且预计与更少的非特异性相关。LIAGT对许多长期冷冻保存的同种异体抗血清的极高敏感性是改良试验保留的特性,并且与储存期间的IgG聚集有关。