Suppr超能文献

超高效液相色谱串联质谱法测定消毒产品中的22种抗生素

[Determination of 22 antibiotics in disinfection products by ultra-performance liquid chromatography tandem mass spectrometry].

作者信息

Wang Junlin, Hu Zhengyan, Feng Liang, Zheng Yibin, Jiang Wei, Zhang Jingshun, Cai Zengxuan

机构信息

Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China.

出版信息

Wei Sheng Yan Jiu. 2019 Jan;48(1):129-135.

Abstract

OBJECTIVE

To develop a method for simultaneous determination of 5 nitroimidazole antibiotics and 17 sulfonamides antibiotics in disinfection products by ultra-performance liquid chromatography tandem mass spectrometry(UPLC-MS/MS).

METHODS

Samples were spiked with isotope internal standard, and then extracted by 2% formic acid solution and acetonitrile with ultrasonic, followed by MCX column to remove matrix interference and for enrichment. The supernatants were diluted with 2% formic acid solution before loading on the columns, then washed with 2% formic acid solution and methanol respectively, eluted with 5% ammonium methanol. The separation was performed on a CORTECS~(TM) UPLC C_(18)(100 mm×2. 1 mm, 1. 6 μm) column by using 0. 1% formic acid solution and 0. 1% formic acid acetonitrile as mobile phase with gradient elution. The antibiotics were analyzed by UPLC-MS/MS.

RESULTS

The linear ranges of 22 antibiotics were 0. 05-5. 0 ng/mL and the correlation coefficients were greater than 0. 999. The limits of detection(LODs) were 0. 03-0. 15 μg/kg and the recoveries were 84. 3%-121. 2% with the relative standard deviations were 1. 13%-8. 43%(n=6). The method was successfully used to detect the content of antibiotics in 20 disinfection products, 45% of samples had been detected positively.

CONCLUSION

This method is simple, sensitive, selective and accurate, and could be applied for simultaneous detection of antibiotics in disinfection products.

摘要

目的

建立超高效液相色谱串联质谱法(UPLC-MS/MS)同时测定消毒产品中5种硝基咪唑类抗生素和17种磺胺类抗生素的方法。

方法

样品加入同位素内标,用2%甲酸溶液和乙腈超声提取,经MCX柱去除基质干扰并富集。上清液用2%甲酸溶液稀释后上样,依次用2%甲酸溶液和甲醇洗涤,用5%氨化甲醇洗脱。采用CORTECS™ UPLC C₁₈(100 mm×2.1 mm,1.6 μm)色谱柱,以0.1%甲酸溶液和0.1%甲酸乙腈为流动相进行梯度洗脱,用UPLC-MS/MS分析抗生素。

结果

22种抗生素的线性范围为0.05 - 5.0 ng/mL,相关系数大于0.999。检出限(LOD)为0.03 - 0.15 μg/kg,回收率为84.3% - 121.2%,相对标准偏差为1.13% - 8.43%(n = 6)。该方法成功用于检测20种消毒产品中抗生素的含量,45%的样品检测呈阳性。

结论

该方法简便、灵敏、选择性好、准确,可用于同时检测消毒产品中的抗生素。