T -relaxation-under-spin-tagging (TRUST) is an MR technique for the non-invasive assessment of whole-brain cerebral oxygen extraction fraction (OEF), through measurement of the venous blood T relaxation time in the sagittal sinus. A key limitation of TRUST, however, is the lack of spatial specificity of the measurement. We sought to develop a modified TRUST sequence, selective localized TRUST (SL-TRUST), having sensitivity to venous blood T within a targeted brain region, and therefore achieving spatially localized measurements of cerebral tissue OEF, while still retaining acquisition in the sagittal sinus.
A method for selective localization of TRUST sequence was developed, and the reproducibility of the technique was evaluated in healthy participants. Regional measurements were achieved for a single hemisphere and for a 3D-localized 70 × 70 × 80 mm tissue region using SL-TRUST and compared to a global TRUST measure. An additional measure of venous blood T in the sagittal sinus was used to estimate subject-specific hematocrit. Six subjects were scanned over 4 sessions, including intra-session repeat measurements.
The average T in the sagittal sinus was found to be 60.8 ± 8.9, 62.7 ± 7.9, 64.6 ± 8.4, and 66.3 ± 10.3 ms (mean ± SD) for conventional TRUST, global SL-TRUST, hemispheric SL-TRUST, and 3D-localized SL-TRUST, respectively. Intra-, inter-session, and inter-subject coefficients of variation for OEF using SL-TRUST were found to be comparable and in some cases superior to those obtained using TRUST.
OEF comparison of 2 contralateral regions was achievable in under 5 min suggesting SL-TRUST offers potential for quantifying regional OEF differences in both healthy and clinical populations.
T-自旋标记(TRUST)是一种 MR 技术,通过测量矢状窦静脉血 T 弛豫时间,可无创评估全脑脑氧摄取分数(OEF)。然而,TRUST 的一个关键局限性是测量缺乏空间特异性。我们试图开发一种改良的 TRUST 序列,即选择性局部 TRUST(SL-TRUST),该序列对目标脑区的静脉血 T 具有敏感性,从而实现脑组织 OEF 的空间局部测量,同时仍保留在矢状窦中的采集。
开发了一种选择性局部 TRUST 序列的方法,并在健康参与者中评估了该技术的可重复性。使用 SL-TRUST 对单个半球和 3D 局部化的 70×70×80mm 组织区域进行了区域测量,并与全局 TRUST 测量进行了比较。还使用矢状窦中的静脉血 T 额外测量来估计受试者的红细胞压积。6 名受试者在 4 次扫描中进行了扫描,包括单次扫描中的重复测量。
发现常规 TRUST、全局 SL-TRUST、半球 SL-TRUST 和 3D 局部化 SL-TRUST 的矢状窦平均 T 分别为 60.8±8.9、62.7±7.9、64.6±8.4 和 66.3±10.3ms(平均值±标准差)。使用 SL-TRUST 测量 OEF 的 Intra、Inter 会话和 Inter 受试者变异系数被发现与使用 TRUST 测量时相当,在某些情况下甚至优于使用 TRUST 测量时。
在不到 5 分钟的时间内,可实现 2 个对侧区域的 OEF 比较,表明 SL-TRUST 有可能在健康和临床人群中定量评估区域 OEF 差异。