使用容积导航评估自旋标记(TRUST)脑氧测量中受试者运动对 T 弛豫的影响。

Assessing the effects of subject motion on T relaxation under spin tagging (TRUST) cerebral oxygenation measurements using volume navigators.

机构信息

Harvard-MIT Health Sciences and Technology, Institute for Medical Engineering & Science, MIT, Cambridge, Massachusetts, USA.

Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.

出版信息

Magn Reson Med. 2017 Dec;78(6):2283-2289. doi: 10.1002/mrm.26616. Epub 2017 Feb 28.

Abstract

PURPOSE

Subject motion may cause errors in estimates of blood T when using the T -relaxation under spin tagging (TRUST) technique on noncompliant subjects like neonates. By incorporating 3D volume navigators (vNavs) into the TRUST pulse sequence, independent measurements of motion during scanning permit evaluation of these errors.

METHODS

The effects of integrated vNavs on TRUST-based T estimates were evaluated using simulations and in vivo subject data. Two subjects were scanned with the TRUST+vNav sequence during prescribed movements. Mean motion scores were derived from vNavs and TRUST images, along with a metric of exponential fit quality. Regression analysis was performed between T estimates and mean motion scores. Also, motion scores were determined from independent neonatal scans.

RESULTS

vNavs negligibly affected venous blood T estimates and better detected subject motion than fit quality metrics. Regression analysis showed that T is biased upward by 4.1 ms per 1 mm of mean motion score. During neonatal scans, mean motion scores of 0.6 to 2.0 mm were detected.

CONCLUSION

Motion during TRUST causes an overestimate of T , which suggests a cautious approach when comparing TRUST-based cerebral oxygenation measurements of noncompliant subjects. Magn Reson Med 78:2283-2289, 2017. © 2017 International Society for Magnetic Resonance in Medicine.

摘要

目的

在对不配合的受试者(如新生儿)使用自旋标记(TRUST)技术下的 T -弛豫时间(T )估计时,由于受试者运动,可能会导致 T 估计值出现误差。通过将 3D 容积导航(vNavs)纳入 TRUST 脉冲序列,在扫描过程中可以独立测量运动,从而评估这些误差。

方法

使用模拟和体内受试者数据评估了集成 vNavs 对基于 TRUST 的 T 估计的影响。使用 TRUST+vNav 序列对 2 名受试者进行扫描,同时进行规定的运动。从 vNavs 和 TRUST 图像中得出平均运动评分,以及指数拟合质量的度量标准。对 T 估计值和平均运动评分之间进行回归分析。此外,还从独立的新生儿扫描中确定了运动评分。

结果

vNavs 对静脉血 T 估计值的影响可以忽略不计,且比拟合质量度量标准更好地检测到受试者运动。回归分析表明,T 每增加 1 毫米的平均运动评分,就会向上偏倚 4.1 毫秒。在新生儿扫描期间,检测到 0.6 至 2.0 毫米的平均运动评分。

结论

TRUST 过程中的运动导致 T 的高估,这表明在比较不配合的受试者的基于 TRUST 的脑氧合测量值时,应谨慎使用。磁共振医学 78:2283-2289, 2017。© 2017 国际磁共振学会。

相似文献

3
Empirical model of human blood transverse relaxation at 3 T improves MRI T oximetry.
Magn Reson Med. 2017 Jun;77(6):2364-2371. doi: 10.1002/mrm.26311. Epub 2016 Jul 6.
6
Multisite evaluations of a T2 -relaxation-under-spin-tagging (TRUST) MRI technique to measure brain oxygenation.
Magn Reson Med. 2016 Feb;75(2):680-7. doi: 10.1002/mrm.25627. Epub 2015 Apr 4.
7
Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration.
Magn Reson Med. 2017 Dec;78(6):2127-2135. doi: 10.1002/mrm.26951. Epub 2017 Oct 5.
8
Vessel-specific quantification of neonatal cerebral venous oxygenation.
Magn Reson Med. 2019 Sep;82(3):1129-1139. doi: 10.1002/mrm.27788. Epub 2019 May 7.

引用本文的文献

2
Volume-localized measurement of oxygen extraction fraction in the brain using MRI.
Magn Reson Med. 2019 Oct;82(4):1412-1423. doi: 10.1002/mrm.27823. Epub 2019 May 27.
3
Characterization of MRI techniques to assess neonatal brain oxygenation and blood flow.
NMR Biomed. 2019 Jul;32(7):e4103. doi: 10.1002/nbm.4103. Epub 2019 Apr 30.
4
Whole-slice mapping of GABA and GABA at 7T via adiabatic MEGA-editing, real-time instability correction, and concentric circle readout.
Neuroimage. 2019 Jan 1;184:475-489. doi: 10.1016/j.neuroimage.2018.09.039. Epub 2018 Sep 19.
5
Exploring early human brain development with structural and physiological neuroimaging.
Neuroimage. 2019 Feb 15;187:226-254. doi: 10.1016/j.neuroimage.2018.07.041. Epub 2018 Jul 21.
6
Quantitative assessment of cerebral venous blood T in mouse at 11.7T: Implementation, optimization, and age effect.
Magn Reson Med. 2018 Aug;80(2):521-528. doi: 10.1002/mrm.27046. Epub 2017 Dec 21.

本文引用的文献

1
Effects of Resolution and Registration Algorithm on the Accuracy of EPI vNavs for Real Time Head Motion Correction in MRI.
Conf Comput Vis Pattern Recognit Workshops. 2016 Jun-Jul;2016:583-591. doi: 10.1109/CVPRW.2016.79. Epub 2016 Dec 19.
2
Empirical model of human blood transverse relaxation at 3 T improves MRI T oximetry.
Magn Reson Med. 2017 Jun;77(6):2364-2371. doi: 10.1002/mrm.26311. Epub 2016 Jul 6.
3
Perioperative cerebral hemodynamics and oxygen metabolism in neonates with single-ventricle physiology.
Biomed Opt Express. 2015 Nov 9;6(12):4749-67. doi: 10.1364/BOE.6.004749. eCollection 2015 Dec 1.
5
T1 and T2 values of human neonatal blood at 3 Tesla: Dependence on hematocrit, oxygenation, and temperature.
Magn Reson Med. 2016 Apr;75(4):1730-5. doi: 10.1002/mrm.25775. Epub 2015 May 18.
6
Multisite evaluations of a T2 -relaxation-under-spin-tagging (TRUST) MRI technique to measure brain oxygenation.
Magn Reson Med. 2016 Feb;75(2):680-7. doi: 10.1002/mrm.25627. Epub 2015 Apr 4.
7
Reduced fetal cerebral oxygen consumption is associated with smaller brain size in fetuses with congenital heart disease.
Circulation. 2015 Apr 14;131(15):1313-23. doi: 10.1161/CIRCULATIONAHA.114.013051. Epub 2015 Mar 11.
8
Head motion during MRI acquisition reduces gray matter volume and thickness estimates.
Neuroimage. 2015 Feb 15;107:107-115. doi: 10.1016/j.neuroimage.2014.12.006. Epub 2014 Dec 10.
9
Rapid T2- and susceptometry-based CMRO2 quantification with interleaved TRUST (iTRUST).
Neuroimage. 2015 Feb 1;106:441-50. doi: 10.1016/j.neuroimage.2014.10.061. Epub 2014 Nov 4.
10
Non-invasive assessment of neonatal brain oxygen metabolism: A review of newly available techniques.
Early Hum Dev. 2014 Oct;90(10):695-701. doi: 10.1016/j.earlhumdev.2014.06.009. Epub 2014 Jul 11.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验