A simple and reliable method using liquid chromatography with diode array detector was developed for the simultaneous determination of florfenicol and thiamphenicol in medicated feed. The analytes were extracted from the minced feed with methanol and ethyl acetate (1:1, v/v). Next, the extract was further cleaned up by dispersive solid phase extraction using anhydrous magnesium sulfate, PSA and C18 sorbents. Finally, 1 mL of extract was evaporated, the residue resuspended in Milli-Q water, and filtered. The method was validated in-house at medicated levels, in the concentration range 10-300 µg/mL (50-1500 mg/kg). Values of <6.5% and <6.0% were found, respectively, for repeatability and within-laboratory reproducibility. The LODs for the two fenicols were 2.4-5.3 mg/kg, while the LOQs were 3.8-5.6 mg/kg. The expanded uncertainty was estimated to be in the range of 10.0-14.5%, depending on the analyte. Recoveries varied from 81.7% to 97.5%. The methodology was applied to the analysis of animal feedingstuffs collected from poultry and pig farms.

摘要

建立了一种使用二极管阵列检测器的液相色谱法,用于同时测定饲料药物中的氟苯尼考和甲砜霉素。分析物用甲醇和乙酸乙酯(1:1,v/v)从切碎的饲料中提取。然后,用无水硫酸镁、PSA 和 C18 吸附剂进行分散固相萃取进一步净化提取液。最后,将 1 mL 提取液蒸发,残渣用 Milli-Q 水重悬并过滤。该方法在药物浓度范围内(10-300 µg/mL,50-1500 mg/kg)在内部进行了验证。重复性和实验室内部再现性分别为<6.5%和<6.0%。两种芬考的检出限为 2.4-5.3 mg/kg,定量限为 3.8-5.6 mg/kg。扩展不确定度估计在 10.0-14.5%之间,取决于分析物。回收率为 81.7%-97.5%。该方法应用于从家禽和养猪场采集的动物饲料的分析。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验