Comparison of Silent Navigator Waveform Generation Methods.

机构信息

Global MR Applications and Workflow, GE Healthcare Japan.

Office of Radiation Technology, Keio University Hospital.

出版信息

Magn Reson Med Sci. 2020 May 1;19(2):154-158. doi: 10.2463/mrms.tn.2018-0168. Epub 2019 May 30.

Abstract

The silent navigator technique utilizes a non-selective excitation and an appropriate respiratory waveform generation method is necessary for an accurate motion detection. We compared three methods for silent navigator waveform generation. The profile generation method with coil selection (prof-selection) resulted in a high cross correlation with bellows signals and a large respiration amplitude. The prof-selection method should be used for silent navigator waveform generation.

摘要

静默导航技术利用非选择性激发,因此需要采用适当的呼吸波形生成方法来实现精确的运动检测。我们比较了三种静默导航波形生成方法。采用线圈选择的廓线生成方法(prof-selection)与风箱信号具有较高的互相关系数,且呼吸幅度较大。因此,prof-selection 方法应被用于静默导航波形生成。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/268c/7232032/409ef79b1f28/mrms-19-154-g1.jpg

相似文献

1
Comparison of Silent Navigator Waveform Generation Methods.
Magn Reson Med Sci. 2020 May 1;19(2):154-158. doi: 10.2463/mrms.tn.2018-0168. Epub 2019 May 30.
2
Direct Comparison of Respiration-Correlated Four-Dimensional Magnetic Resonance Imaging Reconstructed Using Concurrent Internal Navigator and External Bellows.
Int J Radiat Oncol Biol Phys. 2017 Mar 1;97(3):596-605. doi: 10.1016/j.ijrobp.2016.11.004. Epub 2016 Nov 9.
3
Silent navigator-triggered silent MRI of the abdomen.
Magn Reson Med. 2018 Apr;79(4):2170-2175. doi: 10.1002/mrm.26869. Epub 2017 Aug 7.
4
Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator.
IEEE Trans Med Imaging. 2018 Aug;37(8):1751-1760. doi: 10.1109/TMI.2018.2808699. Epub 2018 Feb 22.
8
Motion detection improvement of a pencil-beam navigator echo using a gradient reversal technique.
Magn Reson Imaging. 2015 Nov;33(9):1168-1172. doi: 10.1016/j.mri.2015.06.020. Epub 2015 Jun 25.
9
Usefulness of the navigator-echo triggering technique for free-breathing three-dimensional magnetic resonance cholangiopancreatography.
Magn Reson Imaging. 2013 Apr;31(3):396-400. doi: 10.1016/j.mri.2012.08.009. Epub 2012 Oct 25.
10
Retrospective motion gating in cardiac MRI using a simultaneously acquired navigator.
NMR Biomed. 2018 Mar;31(3). doi: 10.1002/nbm.3874. Epub 2017 Dec 20.

引用本文的文献

1
MR Imaging in the 21st Century: Technical Innovation over the First Two Decades.
Magn Reson Med Sci. 2022 Mar 1;21(1):71-82. doi: 10.2463/mrms.rev.2021-0011. Epub 2021 Apr 16.

本文引用的文献

1
Silent navigator-triggered silent MRI of the abdomen.
Magn Reson Med. 2018 Apr;79(4):2170-2175. doi: 10.1002/mrm.26869. Epub 2017 Aug 7.
2
Motion detection improvement of a pencil-beam navigator echo using a gradient reversal technique.
Magn Reson Imaging. 2015 Nov;33(9):1168-1172. doi: 10.1016/j.mri.2015.06.020. Epub 2015 Jun 25.
3
Usefulness of the navigator-echo triggering technique for free-breathing three-dimensional magnetic resonance cholangiopancreatography.
Magn Reson Imaging. 2013 Apr;31(3):396-400. doi: 10.1016/j.mri.2012.08.009. Epub 2012 Oct 25.
4
A k-space analysis of small-tip-angle excitation. 1989.
J Magn Reson. 2011 Dec;213(2):544-57. doi: 10.1016/j.jmr.2011.09.023.
5
Motion correction using coil arrays (MOCCA) for free-breathing cardiac cine MRI.
Magn Reson Med. 2011 Aug;66(2):467-75. doi: 10.1002/mrm.22854. Epub 2011 Feb 24.
6
Auditory noise associated with MR procedures: a review.
J Magn Reson Imaging. 2000 Jul;12(1):37-45. doi: 10.1002/1522-2586(200007)12:1<37::aid-jmri5>3.0.co;2-i.
7
Algorithms for extracting motion information from navigator echoes.
Magn Reson Med. 1996 Jul;36(1):117-23. doi: 10.1002/mrm.1910360120.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验