Biological surface electromyographic switch and necklace-type button switch control as an augmentative and alternative communication input device: a feasibility study.

作者信息

Lee DongGeon, Lee SeungJun, Lee Kuem Ju, Lee GyuChang

机构信息

Department of Physical Therapy, Graduate School of Kyungnam University, Changwon, Republic of Korea.

J.MARPLE Inc., R&D Team, Seoul, Republic of Korea.

出版信息

Australas Phys Eng Sci Med. 2019 Sep;42(3):839-851. doi: 10.1007/s13246-019-00766-1. Epub 2019 Jun 3.

Abstract

Augmentative and alternative communication (AAC) is an approach used to supplement, improve, and support the communication of those with speech or language impairments. We developed an AAC device for diverse approaches, using an electromyographic (EMG) switch and a necklace-type button switch. The EMG switch comprised an EMG signal processor and a switch interface processor. EMG signals were processed using an electrode through the stages of signal acquisition, amplification, filtering, rectification, and smoothing. In the switch interface processor, the microprocessor determined the switch as ON or OFF in response to an input EMG signal and then converted the EMG signal into a keyboard signal, which was transmitted to a smart device via Bluetooth communication. A similar transmission process was used for the necklace-type button switch, and switch signals were input and processed with general-purpose input/output. The first and second feasibility tests for the EMG switch and button switch were conducted in a total of three test sessions. The result of the feasibility test indicated that the major inconvenience and desired improvement associated with the EMG switch were the intricacy of the AAC device settings. The major inconveniences and desired improvements for the necklace-type button switch involved device shifting, volume and weight, and inconvenience in fixing the switch in various directions. Thus, based on the first and second feasibility tests, we developed an additional device. Finally, the EMG switch and necklace-type button switch developed to remedy the inconveniencies had high feasibility.

摘要

辅助和替代沟通(AAC)是一种用于补充、改善和支持有言语或语言障碍者沟通的方法。我们开发了一种适用于多种方法的AAC设备,使用了肌电图(EMG)开关和项链式按钮开关。EMG开关由一个EMG信号处理器和一个开关接口处理器组成。EMG信号通过电极进行处理,经过信号采集、放大、滤波、整流和平滑等阶段。在开关接口处理器中,微处理器根据输入的EMG信号确定开关为开或关,然后将EMG信号转换为键盘信号,通过蓝牙通信传输到智能设备。项链式按钮开关采用类似的传输过程,开关信号通过通用输入/输出进行输入和处理。对EMG开关和按钮开关进行了总共三次测试会话的首次和第二次可行性测试。可行性测试结果表明,与EMG开关相关的主要不便和期望改进之处在于AAC设备设置的复杂性。项链式按钮开关的主要不便和期望改进之处包括设备移位、体积和重量以及在各个方向固定开关的不便。因此,基于首次和第二次可行性测试,我们开发了一种额外的设备。最后,为解决这些不便而开发的EMG开关和项链式按钮开关具有很高的可行性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验