Suppr超能文献

制备一种新型苄基脲基-β-环糊精柱,并将其应用于 LC/MS/MS 法测定人尿中苯巯基尿酸和苄基巯基尿酸对映体。

Preparation of a new benzylureido-β-cyclodextrin-based column and its application for the determination of phenylmercapturic acid and benzylmercapturic acid enantiomers in human urine by LC/MS/MS.

机构信息

College of Chemistry, Nanchang University, No. 999, Xuefu Ave., Honggutan New District, Nanchang, 330031, Jiangxi, China.

The Collaboration Unit for Field Epidemiology of State Key Laboratory for Infectious Disease Prevention and Control, Nanchang Center for Disease Control and Prevention, No. 833, Lijing Rd., Honggutan New District, Nanchang, 330038, Jiangxi, China.

出版信息

Anal Bioanal Chem. 2019 Aug;411(21):5465-5479. doi: 10.1007/s00216-019-01920-0. Epub 2019 Jun 8.

Abstract

A benzylureido-β-cyclodextrin was synthesized by the reaction of 6-amino-β-cyclodextrin with an active benzyl isocyanate. Then, it was bonded to silica gel by a thiol-ene addition reaction, obtaining a new benzylureido-β-cyclodextrin-based chiral stationary phase (BzCDP). Its chemical structure was characterized by infrared spectroscopy, elemental analysis, and solid-state nuclear magnetic resonance spectroscopy. The BzCDP was successfully used to separate phenylmercapturic acid (PMA) and benzylmercapturic acid (BMA) enantiomers, which were confirmed as biomarkers of exposure to benzene and toluene in human urine. The enantiomeric separations were also optimized through the investigation of related factors. The resolutions of PMA and BMA enantiomers could be up to 2.25 and 2.14, respectively, within 30 min under reversed-phase chromatography. Based on the optimal chromatographic and mass spectrometry conditions, a new LC-MS/MS quantitative method for the PMA and BMA enantiomers was established by negative ion multiple reaction monitoring (MRM) and an isotope-labeled PMA (d-PMA) as an internal standard. The limits of detection (LODs) of enantiomers were less than 0.17 μg/L for PMA and 0.14 μg/L for BMA, and the averaged recoveries of enantiomers were in the range of 86100% for PMA and 86113% for BMA. The method had good reproducibility levels with the RSDs (3.511.3% for intra-day and 3.913.1% for inter-day). The method was successfully applied to urine testing of 60 painting and printing workers. The results showed that only L-PMA was detected in the urine of the Printers, while a high content of L-PMA (27.5106 μg/L) and D-PMA (19.982.8 μg/L) can be detected simultaneously in the urine of the Painters, indicating that benzene pollution was more serious in this group. The positive rate of BMA was rather higher, indicating that toluene pollution was more common than benzene. BMA also existed in the form of two enantiomers (L-BMA and D-BMA), but the difference between the two types of occupational groups was small. It is a meaningful work to deeply study the existence and content of chiral markers in human urine, which will help to better understand and evaluate the harmful effects of benzene series on human beings. Graphical abstract.

摘要

一种苯甲酰基-β-环糊精通过 6-氨基-β-环糊精与活性苯甲酰异氰酸酯的反应合成。然后,通过硫醇-烯加成反应将其键合到硅胶上,得到一种新的苯甲酰基-β-环糊精手性固定相(BzCDP)。通过红外光谱、元素分析和固态核磁共振光谱对其化学结构进行了表征。BzCDP 成功地用于分离苯巯基尿酸(PMA)和苯甲巯基尿酸(BMA)对映体,这两种物质被证实为人体尿液中接触苯和甲苯的生物标志物。通过研究相关因素,还优化了对映体的分离。在反相色谱下,PMA 和 BMA 对映体的分辨率在 30 分钟内分别可达 2.25 和 2.14。基于最佳的色谱和质谱条件,建立了一种新的 LC-MS/MS 定量方法,用于 PMA 和 BMA 对映体的负离子多重反应监测(MRM)和作为内标物的同位素标记的 PMA(d-PMA)。对映体的检测限(LOD)均小于 0.17μg/L(PMA)和 0.14μg/L(BMA),对映体的平均回收率在 86%100%(PMA)和 86%113%(BMA)之间。该方法具有良好的重现性,日内和日间的 RSD 分别为 3.5%11.3%和 3.9%13.1%。该方法成功应用于 60 名绘画和印刷工人的尿液检测。结果表明,只有 L-PMA 出现在印刷工人的尿液中,而油漆工的尿液中同时可以检测到高含量的 L-PMA(27.5106μg/L)和 D-PMA(19.982.8μg/L),表明该组的苯污染更为严重。BMA 的阳性率相当高,表明甲苯污染比苯更为普遍。BMA 也以两种对映体(L-BMA 和 D-BMA)的形式存在,但两种职业群体之间的差异很小。深入研究人体尿液中手性标志物的存在和含量是一项有意义的工作,这将有助于更好地了解和评估苯系物对人类的有害影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验