Department of Medical Laboratory Diagnostics, University Hospital "Sveti Duh", Zagreb, Croatia.
Department of Laboratory Diagnostics, Children's Hospital Zagreb, Zagreb, Croatia.
Biochem Med (Zagreb). 2019 Jun 15;29(2):020709. doi: 10.11613/BM.2019.020709.
In line with the national recommendations, Croatian medical laboratories report urine test strip qualitative analysis results using a categorized scale with defined number of categories. Since concentration ranges for measured analytes have not been provided by national professional authority, it is up to the laboratories to define their own categories. The aim of study was to assess the comparability of concentrations assigned to different categories used in reporting the results of dipstick urinalysis in Croatian laboratories.
A questionnaire was e-mailed to all Croatian medical laboratories (N = 195). They were asked to provide the number of categories and respective concentrations for each parameter. Data were described as numbers and percentages. Values above the upper reference range limit, which were assigned as normal and/or trace category, were considered as false negative.
Response rate was 71% (139/195). Seventy percent (98/139) of laboratories report their results with either higher (77/98; 79%) or lower (2/98; 2%) number of categories, relative to the national recommendation, whereas 19/98 (19%) report their results as concentrations. Great heterogeneity of reporting categories was observed. Multiple categories were assigned to same concentrations and there was a large overlap of concentrations for most categories. Considerable proportion of laboratories reported false negative results for ketones (42%), leukocytes (30%) and glucose (21%).
The concentrations assigned to categories used to report the results of dipstick urinalysis are not comparable among Croatian medical laboratories. There is an urgent need for harmonization and standardization of reporting the results of urine dipstick analysis in Croatia.
根据国家建议,克罗地亚医学实验室使用分类刻度报告尿试纸定性分析结果,其中定义了类别数。由于国家专业机构尚未提供测量分析物的浓度范围,因此由实验室自行定义类别。本研究的目的是评估克罗地亚实验室报告尿试纸分析结果时使用的不同类别所分配的浓度的可比性。
向所有克罗地亚医学实验室(N=195)发送了一份电子问卷。他们被要求提供每个参数的类别数和相应的浓度。数据以数字和百分比表示。超过上限参考范围的赋值为正常和/或痕量类别的值被视为假阴性。
回复率为 71%(139/195)。70%(98/139)的实验室报告结果的类别数高于(77/98;79%)或低于(2/98;2%)国家建议,而 19/98(19%)报告结果为浓度。报告类别存在很大的异质性。多个类别分配给相同的浓度,并且大多数类别之间的浓度重叠很大。相当一部分实验室报告了酮(42%)、白细胞(30%)和葡萄糖(21%)的假阴性结果。
克罗地亚医学实验室用于报告尿试纸分析结果的类别所分配的浓度不可比。克罗地亚急需协调和标准化报告尿液试纸分析的结果。