对用3号聚乙醇酸910缝线打成的推进结在暴露于空气、平衡电解质溶液或马腹部脂肪中的结持力、安全性、重量和体积进行体外评估。

In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat.

作者信息

McGlinchey Leah, Boone Lindsey H, Munsterman Amelia S, Coleridge Matthew O D, Rosanowski Sarah M, Farag Ramsis, Hanson R Reid

出版信息

Am J Vet Res. 2019 Jul;80(7):709-716. doi: 10.2460/ajvr.80.7.709.

Abstract

OBJECTIVE

To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots.

SAMPLE

315 knots tied and tested in vitro.

PROCEDURES

United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile strength of suture and knots to failure, and the KHC, RKS, weight, and volume of knots were determined.

RESULTS

Forwarder knots had significantly higher KHC and RKS and lower volume, compared with surgeons' knots. Forwarder knots tied with fat-exposed suture had greater weight, but not volume, than did forwarder knots tied with dry or BES-exposed suture with the same number of throws.

CONCLUSIONS AND CLINICAL RELEVANCE

Results indicated that forwarder knots were superior to surgeon's knots when configured as start knots intended for continuous lines of suture. Exposure to media did not negatively affect mechanical or physical properties of forwarder knots and may improve specific biomechanical functions, including KHC and RKS.

摘要

目的

评估接触平衡电解质溶液(BES)或马腹部脂肪对推进结与外科结的打结保持能力(KHC)、相对结安全性(RKS)、重量和体积的影响。

样本

315个结在体外打结并测试。

程序

使用暴露于空气(干燥[对照])、马腹部脂肪(脂肪暴露)或BES(BES暴露)的美国药典3号聚乙醇酸910缝线,分别打2、3和4个结的推进结以及5、6、7和8个结的外科结。使用万能材料试验机测试缝线和结至断裂的拉伸强度,并测定结的KHC、RKS、重量和体积。

结果

与外科结相比,推进结的KHC和RKS显著更高,体积更小。与用相同投掷次数的干燥或BES暴露缝线打的推进结相比,用脂肪暴露缝线打的推进结重量更大,但体积无差异。

结论及临床意义

结果表明,当作为连续缝线的起始结配置时,推进结优于外科结。接触介质不会对推进结的机械或物理性能产生负面影响,且可能改善特定的生物力学功能,包括KHC和RKS。