Mayampurath Anoop, Volchenboum Samuel L, Sanchez-Pinto L Nelson
1Department of Pediatrics, The University of Chicago, Chicago, IL USA.
2Center for Research Informatics, The University of Chicago, Chicago, IL USA.
NPJ Digit Med. 2018 Jul 25;1:29. doi: 10.1038/s41746-018-0038-0. eCollection 2018.
Pediatric oncology patients are at high risk of developing clinical deterioration and organ dysfunction during their illness. Heart rate variability (HRV) measured using electrocardiography waveforms is associated with increased organ dysfunction and clinical deterioration in adult and pediatric patients in the intensive care unit (ICU). Here, we explore the feasibility of using photoplethysmography (PPG)-derived integer pulse rate variability (PRVi) to estimate HRV and determine its association with organ dysfunction in pediatric oncology patients in the ward and pediatric ICU. The advantage of using PPG sensor data over electrocardiography is its higher availability in most healthcare settings and in wearable technology. In a cohort of 38 patients, reduced median daily PRVi was significantly associated with increase in two pediatric organ dysfunction scores after adjusting for confounders ( < 0.001). PRVi shows promise as a real-time physiologic marker of clinical deterioration using highly-available PPG data, but further research is warranted.
儿科肿瘤患者在患病期间发生临床病情恶化和器官功能障碍的风险很高。使用心电图波形测量的心率变异性(HRV)与重症监护病房(ICU)中的成年和儿科患者器官功能障碍增加及临床病情恶化相关。在此,我们探讨使用基于光电容积脉搏波描记法(PPG)的整数脉率变异性(PRVi)来估计HRV并确定其与病房和儿科ICU中儿科肿瘤患者器官功能障碍的关联的可行性。使用PPG传感器数据而非心电图的优势在于其在大多数医疗环境和可穿戴技术中的更高可用性。在一组38名患者中,在校正混杂因素后,每日PRVi中位数降低与两项儿科器官功能障碍评分的增加显著相关(<0.001)。PRVi有望作为使用高可用性PPG数据的临床病情恶化的实时生理标志物,但仍需进一步研究。