Arcim institute, Im Haberschlai 7, 70794 Filderstadt, Germany.
Int J Cardiol. 2013 Jun 5;166(1):15-29. doi: 10.1016/j.ijcard.2012.03.119. Epub 2012 Jul 17.
BACKGROUND: The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV. METHODS: We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography). RESULTS/CONCLUSIONS: Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
背景:心率变异性(HRV)作为一种临床研究和诊断工具的有用性已在众多研究中得到验证。金标准技术包括分析心电图信号中 RR 间隔的时间序列。然而,一些作者已经使用脉搏周期间隔代替 RR 间隔,因为它们可以从脉搏波(例如光体积描记)信号中确定。此选项通常称为脉搏率变异性(PRV),利用它可以扩展脉搏血氧仪的适用性或简化 HRV 的动态监测。
方法:我们综述了无论底层技术如何(光体积描记法、连续血压监测或 Finapresi、容积描记法),研究 PRV 作为 HRV 估计值的准确性的研究。
结果/结论:结果表明,当受试者处于休息状态时,PRV 的准确性足够,尽管许多研究表明,PRV 对短期变异性的估计有些过高,这反映了呼吸和心血管系统之间的耦合效应。身体活动和一些精神应激源似乎会降低 PRV 和 HRV 的一致性,通常是不可接受的程度。关于传感器位置或检测算法的发现尚无定论。一般来说,由于不同的实验设置和/或分析方法,不同研究的结果大多不可比,这阻碍了定量结论的得出。
Med Eng Phys. 2010-10-25
J Physiol Anthropol. 2020-8-18
Annu Int Conf IEEE Eng Med Biol Soc. 2018-7
J Clin Monit Comput. 2016-12
NPJ Cardiovasc Health. 2025
Phys Eng Sci Med. 2025-8-19
Front Neuroergon. 2025-6-18
J Cardiovasc Dev Dis. 2025-6-6