Raznahan Maedeh, Emamian Mohammad Hassan, Hashemi Hassan, Zeraati Hojjat, Fotouhi Akbar
Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran.
Depute of Research, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
J Curr Ophthalmol. 2018 Dec 27;31(2):188-194. doi: 10.1016/j.joco.2018.12.001. eCollection 2019 Jun.
To measure Horizontal Inequity Index (HI) of unmet refractive error and its changes between 2009 and 2014 in Iran.
The data used in this study was taken from population-based study, Shahroud Eye Cohort Study. The number of participants analyzed in first (2009) and second phases of study (2014) were 5190 and 4737, respectively, and individuals between 40 and 64 years were included. The HI was determined by using the Concentration Index (C) based on the nonlinear (Probit) model, and C was decomposed to identify and quantify the contribution of each factor.
After adjusting for need variables, the results demonstrated that the HI in unmet refractive need decreased from -0.288 (95% CI: 0.370, -0.206) in the 2009 to -0.132 (95% CI: 0.290, -0.028) in 2014. Decomposition of the C showed that level of education and economic status were the greatest contributors with shares of 26.2% and 17.9%, respectively, in reducing the amount of HI in unmet refractive error between 2009 and 2014.
The current study demonstrated that unmet refractive error did not have an equal distribution among economic quintiles, despite the same need for correcting refractive errors. Reducing the amount of HI in unmet refractive error between 2009 and 2014 indicated an improvement in the unmet need in the five years period between two phases of study.
测量伊朗2009年至2014年未矫正屈光不正的水平不公平指数(HI)及其变化。
本研究使用的数据来自基于人群的研究——沙赫鲁德眼队列研究。研究第一阶段(2009年)和第二阶段(2014年)分析的参与者人数分别为5190人和4737人,纳入了40至64岁的个体。HI通过基于非线性(概率单位)模型的浓度指数(C)来确定,并且对C进行分解以识别和量化每个因素的贡献。
在对需求变量进行调整后,结果表明未矫正屈光需求的HI从2009年的-0.288(95%置信区间:0.370,-0.206)降至2014年的-0.132(95%置信区间:0.290,-0.028)。C的分解表明,教育水平和经济状况是最大的贡献因素,在2009年至2014年期间减少未矫正屈光不正的HI量方面,分别占26.2%和17.9%。
当前研究表明,尽管矫正屈光不正的需求相同,但未矫正屈光不正在经济五分位数之间的分布并不均等。2009年至2014年期间未矫正屈光不正的HI量减少表明在研究的两个阶段之间的五年时间里未满足的需求有所改善。