A Comparison of Thermal Changes among Four Different Interproximal Reduction Systems in Orthodontics.

作者信息

Omer Amina Balla Al-Hassan, Sanea Jamal Al

机构信息

Department of Preventive Dental Sciences, Riyadh Colleges of Dentistry and Pharmacy, Riyadh, Kingdom of Saudi Arabia.

Department of Preventive Dental Sciences, Riyadh Colleges of Dentistry and Pharmacy, Riyadh, Kingdom of Saudi Arabia, e-mail:

出版信息

J Contemp Dent Pract. 2019 Jun 1;20(6):738-742.

Abstract

INTRODUCTION

Interproximal enamel stripping is routinely used in orthodontics, different methods were utilized by clinicians to reduce the width of teeth but no previous study addressed the factors affecting the thermal safety of such systems on the dental pulp.

AIM

The present study was conducted to measure thermal changes among four different interproximal reduction (IPR) systems in orthodontics.

MATERIALS AND METHODS

A total of 130 extracted human premolar teeth were used in this study. Teeth were distributed into three experimental groups each having three subgroups and one control group. Thus, a total of 10 subgroups were created of 13 teeth each. Stripping procedures were performed using four diamond tools (burs, discs, saw, and manual strip) with different speed setup, with and without a coolant for the higher speed setup for each tool. A K-type thermocouple wire was positioned in the center of the pulp chamber and was connected to a data logger during the application of stripping procedures. Data were analyzed by the Krushkal-Wallis test using the SPSS PC+ version 21.0 statistical software.

RESULTS

There was a highly statistically significant difference in the mean ranks of temperature values among the four groups with different speed levels. Among the 10 subgroups, the higher change in temperature registered was in the bur and disc groups when operated with the highest recommended speed without a coolant. The change in temperature was statistically significantly higher than the temperature values of other groups (p < 0.001). All recorded temperatures were below the critical temperature (5.5 °C) registered.

CONCLUSION

Based on the results of this study, IPR is a safe procedure on the dental pulp for the teeth with a medium dentin thickness with or without a coolant.

摘要

引言

邻面釉质磨除术在正畸治疗中经常使用,临床医生采用不同方法来减小牙齿宽度,但此前尚无研究探讨此类系统对牙髓热安全性的影响因素。

目的

本研究旨在测量正畸治疗中四种不同邻面减径(IPR)系统的热变化。

材料与方法

本研究共使用了130颗拔除的人类前磨牙。牙齿被分为三个实验组,每组又分为三个亚组,以及一个对照组。因此,共创建了10个亚组,每组13颗牙齿。使用四种不同速度设置的金刚石工具(车针、圆盘、锯片和手动条带)进行磨除操作,每种工具在较高速度设置时使用或不使用冷却液。在进行磨除操作时,将一根K型热电偶丝置于髓腔中心,并连接到数据记录器。使用SPSS PC+ 21.0版统计软件通过Kruskal-Wallis检验对数据进行分析。

结果

在不同速度水平的四组中,温度值的平均秩次存在高度统计学显著差异。在10个亚组中,使用最高推荐速度且不使用冷却液操作时,车针组和圆盘组的温度变化最大。该温度变化在统计学上显著高于其他组的温度值(p < 0.001)。所有记录的温度均低于临界温度(5.5°C)。

结论

基于本研究结果,对于牙本质厚度中等的牙齿,无论有无冷却液,IPR对牙髓都是一种安全的操作。