Suppr超能文献

新生儿血液采样中的误差来源。

Sources of error in neonatal blood sampling.

作者信息

Patel H, Ryan S W, McLain B

机构信息

Department of Paediatrics and Child Health, General Infirmary, Leeds.

出版信息

Arch Dis Child. 1988 Jul;63(7 Spec No):752-3. doi: 10.1136/adc.63.7_spec_no.752.

Abstract

Significant underestimation of blood electrolyte concentrations may occur if less than 1 ml of blood is withdrawn from an indwelling arterial line before taking the sample for analysis. Compared with arterial samples capillary samples give significant overestimations of potassium concentration and carbon dioxide tension, and significant underestimation of oxygen tension.

摘要

如果在从留置动脉导管采集血样进行分析之前抽取的血液少于1毫升,可能会出现血液电解质浓度的严重低估。与动脉血样相比,毛细血管血样会使钾浓度和二氧化碳分压显著高估,而氧分压显著低估。

相似文献

1
Sources of error in neonatal blood sampling.新生儿血液采样中的误差来源。
Arch Dis Child. 1988 Jul;63(7 Spec No):752-3. doi: 10.1136/adc.63.7_spec_no.752.
6
Correlation between capillary and arterial blood gas parameters in an ED.急诊科毛细血管与动脉血气参数的相关性。
Am J Emerg Med. 2013 Feb;31(2):326-9. doi: 10.1016/j.ajem.2012.08.025. Epub 2012 Nov 15.
8
Contamination errors when sampling blood from an arterial line.
Clin Pediatr (Phila). 1993 Aug;32(8):501-3. doi: 10.1177/000992289303200810.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验