手术导板支持和种植体植入部位对静态计算机辅助种植手术精度的影响。

Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery.

机构信息

Department of Oral Surgery and Stomatology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Division of Periodontology, Harvard School of Dental Medicine, Boston, Massachusetts.

出版信息

Clin Oral Implants Res. 2019 Nov;30(11):1067-1075. doi: 10.1111/clr.13520. Epub 2019 Aug 20.

Abstract

OBJECTIVE

To investigate the effect of surgical guide support and implant site location on the accuracy of static Computer-Assisted Implant Surgery (sCAIS) in partially edentulous patients.

MATERIALS AND METHODS

375 replica implants were inserted in 85 study models. Surgical implant placement was done using static 3D printed surgical guides, which were designed to be supported either by all the teeth present in the model (full arch), or by 4-teeth), 3-teeth or 2-teeth. Each study model included three single-tooth gap (STG) situations; one extraction socket site and two implants placed in a distal extension situation. Preplanned and postoperative implant positions were compared using the treatment-evaluation tool in digital software. 3-dimensional and angular deviations were measured. Statistical analysis was done using ANOVA, and pairwise t tests and Bonferroni-Holm's adjustment were applied as a post hoc test.

RESULTS

Accuracy of surgical guides used in sCAIS was significantly affected by the number and type of teeth used for its support. Guides supported by 4 teeth were not significantly different from accuracy of full-arch-supported guides (p > .05). Guide support by posterior teeth was associated with an increased level of accuracy, when compared to anterior teeth guide support. Implants placed in extraction sockets were associated with significantly higher 3D and angular deviation values (p < .05), and surgical guides with a distal extension situation resulted in significantly higher deviation values (p < .05).

CONCLUSION

The number and location of teeth supporting the surgical guide can significantly influence the accuracy of sCAIS, with 4 teeth providing equal accuracy to full-arch guides in (STG) situations.

摘要

目的

研究外科导板的支持和种植体位置对部分无牙颌患者静态计算机辅助种植手术(sCAIS)精度的影响。

材料和方法

将 375 个复制种植体插入 85 个研究模型中。使用静态 3D 打印外科导板进行种植体植入,该导板设计为以下几种情况进行支持:模型中所有牙齿(全弓),或 4 颗牙、3 颗牙或 2 颗牙。每个研究模型包括三个单牙间隙(STG)情况;一个拔牙窝和两个种植体在远中扩展位置。使用数字软件中的治疗评估工具比较术前和术后种植体位置。测量三维和角度偏差。使用方差分析进行统计分析,并应用两两 t 检验和 Bonferroni-Holm 调整作为事后检验。

结果

sCAIS 中使用的外科导板的准确性受用于其支撑的牙齿数量和类型的显著影响。由 4 颗牙齿支撑的导板与全弓支撑导板的准确性无显著差异(p>.05)。与前牙导板支撑相比,后牙导板支撑与更高的准确性相关。放置在拔牙窝中的种植体与显著更高的三维和角度偏差值相关(p<.05),而具有远中扩展情况的外科导板导致显著更高的偏差值(p<.05)。

结论

支撑外科导板的牙齿数量和位置会显著影响 sCAIS 的准确性,在 STG 情况下,4 颗牙提供与全弓导板相同的准确性。