Abstract

PURPOSE

Dynamic navigation systems and surgical guides have been reported to be equally accurate. However, the accuracy of dynamic navigation systems is affected by the movement of the patient tracker fixed to the tooth. We hypothesized that fixing the patient tracker to the oral appliance could improve accuracy. Therefore, this study aimed to compare accuracy between a dynamic navigation system with a patient tracker fixed to an oral appliance and a surgical guide.

METHODS

This observational study was conducted on patients who had undergone complete implant treatment at Kanagawa Dental University from 2020 to September 2024. Fifty implant bodies were placed in 42 patients with anterior tooth defects in both the dynamic navigation and surgical guide groups (25 implants each). DTX Studio™ (Nobel Biocare AG, Kloten, Switzerland) was used to overlay planning data on postoperative Digital Imaging and Communications in Medicine data to calculate entry point, apex point, and angular deviation accuracy.

RESULTS

The entry point, apex point, and angular deviation values were 0.99 ± 0.33 mm, 0.97 ± 0.43 mm, and 2.64 ± 0.87° in the dynamic navigation group and 1.33 ± 0.26 mm, 1.38 ± 0.3 mm, and 3.42 ± 1.03° in the surgical guide group, respectively, differing significantly at all measurement sites (P < 0.01).

CONCLUSIONS

The fixation of the X-clip to the oral appliance improved intra-oral stability and inhibited intraoperative movement of the X-clip, resulting in high accuracy. These results suggest that dynamic navigation by oral appliance fixation is more accurate than surgical guides.

摘要

目的

据报道,动态导航系统和手术导板的准确性相当。然而,动态导航系统的准确性会受到固定在牙齿上的患者追踪器移动的影响。我们假设将患者追踪器固定在口腔矫治器上可以提高准确性。因此,本研究旨在比较将患者追踪器固定在口腔矫治器上的动态导航系统与手术导板之间的准确性。

方法

本观察性研究针对2020年至2024年9月在神奈川齿科大学接受全口种植治疗的患者进行。在动态导航组和手术导板组中,为42例前牙缺损患者植入了50颗种植体(每组25颗)。使用DTX Studio™(瑞士克洛滕诺贝尔生物Care公司)将计划数据叠加在术后医学数字成像和通信数据上,以计算入点、根尖点和角度偏差的准确性。

结果

动态导航组的入点、根尖点和角度偏差值分别为0.99±0.33毫米、0.97±0.43毫米和2.64±0.87°,手术导板组分别为1.33±0.26毫米、1.38±0.3毫米和3.42±1.03°,在所有测量部位均有显著差异(P<0.01)。

结论

将X夹固定在口腔矫治器上可提高口腔内稳定性,并抑制X夹在术中的移动,从而实现高精度。这些结果表明,通过口腔矫治器固定进行的动态导航比手术导板更准确。