• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comparison of indium 111 oxine-labeled platelet aggregation between sutured and argon laser-assisted vascular anastomoses.

作者信息

Fujitani R M, White R A, Kopchok G E, Vlasak J, Marcus C S, White G H

机构信息

Department of Surgery, Harbor--University of California, Los Angeles Medical Center 90509.

出版信息

J Vasc Surg. 1988 Sep;8(3):274-9.

PMID:3138437
Abstract

The thrombogenicity of argon laser-assisted vascular anastomoses (LAVAs) was compared with that of sutured vascular anastomoses (SVAs) by measurement of platelet aggregation at the site of repair in a canine model. Sequential 1 cm longitudinal carotid and femoral arteriotomies (n = 80) or jugular and femoral phlebotomies (n = 80) were performed, with each vessel having two tandem, randomly positioned arteriotomies or phlebotomies separated by a 4 cm length of intact vessel. One incision was repaired by SVA with continuous 6-0 polypropylene sutures and the other by argon LAVA. For the laser fusions, argon laser energy was applied to the adventitial surface of the vessel with a 300 micron fiberoptic probe with 0.5 W power, 1100 joules per square centimeter energy fluence, and 150 second exposure per 1 cm length. The arterial and venous segments of SVAs and LAVAs and an equivalent length of normal vessel were harvested at 48 hours (n = 16, 16, 16), 2 weeks (n = 12, 12, 12), and 4 weeks (n = 12, 12, 12). Autologous indium 111 oxine-labeled platelets were injected intravenously 48 hours before removal of the vascular repairs and the radioactivity of the specimens was determined on removal with a NaI (T1) well-type scintillation counter. Anastomotic platelet adherence index (APAI) was calculated as the ratio of emissions of SVA or LAVA to normal reference vessel.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Comparison of indium 111 oxine-labeled platelet aggregation between sutured and argon laser-assisted vascular anastomoses.
J Vasc Surg. 1988 Sep;8(3):274-9.
2
Argon laser vascular fusion: venous and arterial bursting pressures.
Lasers Surg Med. 1989;9(5):478-81. doi: 10.1002/lsm.1900090509.
3
Argon laser-welded bovine heterograft anastomoses.氩激光焊接的牛异种移植物吻合术。
J Clin Laser Med Surg. 1993 Feb;11(1):1-5. doi: 10.1089/clm.1993.11.1.
4
Comparison of laser-welded and sutured arteriotomies.
Arch Surg. 1986 Oct;121(10):1133-5. doi: 10.1001/archsurg.1986.01400100039007.
5
Preformed confluent endothelial cell monolayers prevent early platelet deposition on vascular prostheses in baboons.预先形成的融合内皮细胞单层可防止狒狒血管假体上早期血小板沉积。
J Vasc Surg. 1988 Sep;8(3):229-35.
6
A comparison of absorbable suture and argon laser welding for lateral repair of arteries.
J Vasc Surg. 1991 Aug;14(2):184-9. doi: 10.1067/mva.1991.28841.
7
Argon laser-assisted anastomoses in medium-size vessels: one-year follow-up.
Lasers Surg Med. 1991;11(3):223-31. doi: 10.1002/lsm.1900110305.
8
Experimental and early clinical evaluation of vascular anastomoses with argon laser fusion and the use of absorbable guy sutures: a preliminary report.
J Vasc Surg. 1990 Oct;12(4):401-6; discussion 406-8.
9
Experimental diode laser-assisted microvascular anastomosis.
J Reconstr Microsurg. 1993 May;9(3):203-10; discussion 210-1. doi: 10.1055/s-2007-1006646.
10
Argon laser-welded arteriovenous anastomoses.
J Vasc Surg. 1987 Nov;6(5):447-53.