Danielewska Monika E, Messner Alina, Werkmeister René M, Placek Michał M, Aranha Dos Santos Valentin, Rękas Marek, Schmetterer Leopold
Wrocław University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wrocław, Poland.
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Transl Vis Sci Technol. 2019 Aug 1;8(4):15. doi: 10.1167/tvst.8.4.15. eCollection 2019 Jul.
To estimate the relationship between the characteristics of the corneal pulse (CP) signal and those of the fundus pulse (FP) signal measured with a combined noncontact ultrasonic and laser interferometry technique in healthy subjects.
Twenty-two healthy subjects participated in experiments that included measurements of intraocular pressure, ocular pulse amplitude, ocular biometry, blood pressure, and heart rate. Additionally, simultaneous recordings of CP and FP signals were acquired with a noncontact ultrasonic device combined with laser interferometry. Subsequently, ocular perfusion pressure (OPP) and the time and spectral parameters of CP and FP signals were computed. A system model was proposed to relate the FP signal to the CP signal.
The system model revealed that the eye globe transfers information between signals of the posterior and anterior eye, relatively amplifying higher spectral harmonics. The amplitude of the second CP harmonic is predicted by FP and OPP ( = 0.468, = 0.002). Partial correlation analysis showed that the CP signal parameters are statistically significantly correlated with those of the FP signal and OPP, after correcting for age and sex.
The eye globe can be viewed as a , in which the CP characteristic changes in relation to the fundus pulsation. The FP signal and OPP have an impact on the variations of the CP signal morphology.
Investigation of differences between the characteristics of the anterior and posterior tissue movements is a promising method for evaluating the role of circulatory and biomechanical components in the pathophysiology of ocular diseases.
评估在健康受试者中,采用非接触超声和激光干涉测量技术联合测量得到的角膜脉搏(CP)信号特征与眼底脉搏(FP)信号特征之间的关系。
22名健康受试者参与了实验,实验内容包括测量眼压、眼脉搏振幅、眼部生物测量、血压和心率。此外,使用结合激光干涉测量的非接触超声设备同时记录CP和FP信号。随后,计算眼灌注压(OPP)以及CP和FP信号的时间和频谱参数。提出了一个系统模型来关联FP信号和CP信号。
系统模型显示,眼球在眼后段和前段信号之间传递信息,相对放大了较高的频谱谐波。FP和OPP可预测CP第二谐波的振幅(r = 0.468,P = 0.002)。偏相关分析表明,在校正年龄和性别后,CP信号参数与FP信号和OPP的参数在统计学上具有显著相关性。
眼球可被视为一个……,其中CP特征随眼底搏动而变化。FP信号和OPP对CP信号形态的变化有影响。
研究眼前段和眼后段组织运动特征之间的差异是评估循环和生物力学成分在眼部疾病病理生理学中作用的一种有前景的方法。