• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects.

作者信息

Sutter F, Raveh J

机构信息

Research Associate Institute Straumann AG, Waldenburg, Switzerland.

出版信息

Int J Oral Maxillofac Surg. 1988 Aug;17(4):267-74. doi: 10.1016/s0901-5027(88)80055-9.

DOI:10.1016/s0901-5027(88)80055-9
PMID:3139801
Abstract

The biomechanical and design principles of the titanium hollow screw and reconstruction plate (THRP) system are described. Physiologically advantageous load transmission, a biocompatible implant material with sufficient strength and a surface structure favorable to biological stabilization are discussed. The design of the fixation between the cross-split screwhead and the plate hole gives a rigid and stable plate fixation even without contact between plate underside and bone. Blood perfusion and bone strength will therefore not be affected. Full functional loading with only 2-3 fixation screws for each plate end is possible. Further technical advantages of the THRP system are the possibility of lingual plate application and integration of a three-dimensional adjustable condylar prothesis.

摘要

相似文献

1
Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects.
Int J Oral Maxillofac Surg. 1988 Aug;17(4):267-74. doi: 10.1016/s0901-5027(88)80055-9.
2
[Mandibular reconstruction with the titanium-hollow screw-reconstruction plate system (THORP)].
Schweiz Monatsschr Zahnmed. 1990;100(6):701-8.
3
Titanium-coated hollow screw and reconstruction plate system (THORP) in mandibular reconstruction.
J Craniomaxillofac Surg. 1988 May;16(4):173-83. doi: 10.1016/s1010-5182(88)80043-x.
4
[Titanium-coated hollow screw and reconstruction plate system for the bridging of jaw defects. II. Possible reconstruction variants with the THRP system].
Chirurg. 1985 May;56(5):337-44.
5
Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects.
J Oral Maxillofac Surg. 1984 May;42(5):281-94. doi: 10.1016/0278-2391(84)90108-3.
6
Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases.钛质中空螺钉重建钢板(THORP)系统用于下颌骨重建:62例病例评估
Plast Reconstr Surg. 1988 Nov;82(5):804-14. doi: 10.1097/00006534-198811000-00013.
7
Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: bridging of defects.
Otolaryngol Clin North Am. 1987 Aug;20(3):535-58.
8
Mandibular reconstruction with the THORP condylar prosthesis after hemimandibulectomy.
J Craniomaxillofac Surg. 1989 Feb;17(2):78-87. doi: 10.1016/s1010-5182(89)80050-2.
9
[Bridging of the defect by the lingual approach and bone graft fixation in the mandible with the THRP (titanium-coated hollow-screw and reconstruction plate) system].
Schweiz Monatsschr Zahnmed (1984). 1984 Feb;94(2):134-42.
10
Does fixation method affects temporomandibular joints after mandibular advancement?固定方式是否会影响下颌前伸术后的颞下颌关节?
J Craniomaxillofac Surg. 2018 Jun;46(6):923-931. doi: 10.1016/j.jcms.2018.03.024. Epub 2018 Apr 7.

引用本文的文献

1
Assessment of Bite Force in Patients Treated with 2.0-mm Traditional Miniplates versus 2.0-mm Locking Plates for Mandibular Fracture.使用2.0毫米传统微型钢板与2.0毫米锁定钢板治疗下颌骨骨折患者的咬合力评估
Craniomaxillofac Trauma Reconstr. 2016 Mar;9(1):62-8. doi: 10.1055/s-0035-1563697. Epub 2015 Sep 21.
2
Bite Force Evaluation of Conventional Plating System Versus Locking Plating System for Mandibular Fracture.传统接骨板系统与锁定接骨板系统在下颌骨骨折中的咬合力评估
J Maxillofac Oral Surg. 2015 Dec;14(4):972-8. doi: 10.1007/s12663-015-0764-7. Epub 2015 Mar 10.
3
Comparative evaluation of 2.0-mm locking plate system vs. 2.0-mm nonlocking plate system for mandibular fractures--a retrospective study.
2.0毫米锁定钢板系统与2.0毫米非锁定钢板系统在下颌骨骨折治疗中的对比评估——一项回顾性研究
Oral Maxillofac Surg. 2013 Dec;17(4):287-91. doi: 10.1007/s10006-012-0377-y. Epub 2012 Nov 25.