Grupo de Estudos e Pesquisas em Funcao Autonomica Cardiaca (GEFAC), Centro Universitario Euro Americano - UNIEURO, Brasilia, DF, BR.
Laboratorio de Fisiologia do Exercicio, Faculdade de Educacao Fisica, Universidade de Brasilia, Brasilia, DF, BR.
Clinics (Sao Paulo). 2019;74:e806. doi: 10.6061/clinics/2019/e806. Epub 2019 Aug 12.
The reliability of heart rate variability (HRV) analysis is not yet fully understood, especially considering different body positions and the mathematical influence of heart rate. The aim of this study was to evaluate the reliability of HRV in supine and standing positions, with and without mathematical adjustment of HRV by the average R-R interval (iRR).
We evaluated 37 young males (23.1±4 years; 25.1±3 kg/m2). A 5-min segment of the iRR was collected in the supine and standing positions on three occasions separated by 48-hour intervals. Absolute and relative reliability of temporal and spectral indices were assessed by the coefficient of variation (CV) and the intraclass correlation coefficient (ICC), respectively.
We did not observe differences in HRV indices in the three occasions in the supine or standing position (p>0.05). Moderate to good reproducibility was observed for temporal and spectral indices of HRV in the supine position (ICC: 0.65-0.89; CV: 0.9-19.8). In the orthostatic position, low to good reproducibility was observed (ICC: 0.35-0.89; CV: 1.1-34.8), with higher ICCs for temporal indices. After mathematical adjustment, only a small modification in HRV reliability was observed in both positions.
In young adult males, the mathematical adjustment of HRV by the average iRR led to a nonsignificant effect on HRV reliability. Additionally, HRV reliability is dependent on body position and the index analyzed. Promising measures in both supine and standing positions include r-MSSD and the HF band (parasympathetic indices).
心率变异性(HRV)分析的可靠性尚未得到充分理解,尤其是考虑到不同的体位和心率的数学影响。本研究旨在评估仰卧位和直立位 HRV 的可靠性,以及是否通过平均 R-R 间期(iRR)对 HRV 进行数学调整。
我们评估了 37 名年轻男性(23.1±4 岁;25.1±3kg/m2)。在三个间隔 48 小时的时间内,在仰卧位和直立位分别采集 5 分钟的 iRR 片段。通过变异系数(CV)和组内相关系数(ICC)分别评估时域和频域指标的绝对和相对可靠性。
我们在仰卧位或直立位的三个时间点均未观察到 HRV 指标的差异(p>0.05)。仰卧位时 HRV 的时域和频域指标表现出中等至良好的可重复性(ICC:0.65-0.89;CV:0.9-19.8)。在直立位时,观察到低到良好的可重复性(ICC:0.35-0.89;CV:1.1-34.8),其中时域指标的 ICC 更高。经过数学调整后,仅在两个位置观察到 HRV 可靠性的微小变化。
在年轻成年男性中,通过平均 iRR 对 HRV 进行数学调整对 HRV 可靠性没有显著影响。此外,HRV 的可靠性取决于体位和分析的指标。仰卧位和直立位都有希望的指标包括 r-MSSD 和 HF 波段(副交感神经指标)。