与CBCT模型扫描相比,全牙列有牙颌患者中口腔内扫描仪(IOS)的准确性:一项体内研究

Accuracy of IOS in Full-Arch Dentate Patients Compared to CBCT Cast-Scanning. An In-Vivo Study.

作者信息

Michelinakis G, Apostolakis D, Pavlakis E, Kourakis G, Papavasiliou G

机构信息

Private Dental Practice.

Assistant Professor, Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens.

出版信息

Eur J Prosthodont Restor Dent. 2019 Aug 29;27(3):122-130. doi: 10.1922/EJPRD_01906Michelinakis09.

Abstract

Twenty fully-dentate patients were enrolled in the study.Full-arch maxillary and mandibular PVS impressions were acquired using stock metal trays and the dual mix technique. A full-arch maxillary and mandibular intraoral scanner (IOS) was also obtained using the Trios IOS. The impressions were cast and subsequently scanned using a Planmeca Promax cone beam computed tomography (CBCT) scanner. The casts were also scanned in a Desktop Scanner for reference(7series Dental Wings). DICOM files from the CBCT device were converted into stl files. The.stl files from the CBCT and IOS devices were compared for accuracy against the reference files from the Desktop Scanner using a 3D surface measurement software. Statistical analysis was carried out using SPSS software. Trios had a smaller error (median = 39μm) than CBCT (median = 62μm),a statistically significant difference between the 2 modalities (z=-4.6, p⟨0.005).Concerning the IOS, the anterior teeth presented with a smaller error (42±16μm) as opposed to the posterior teeth (47±16μm), a significant difference (t(39)=-2.4, p=0,019). There were no significant differences in IOS mean accuracy between maxilla and mandible or between left and right quadrants. Fullarch digitization using the Trios IOS is significantly more accurate compared to CBCT scanning of the relevant plaster models. Anterior teeth Trios IOS is statistically more accurate compared to posterior teeth IOS.

摘要

本研究纳入了20名全口牙齿完整的患者。使用通用金属托盘和双混技术获取全牙弓上颌和下颌的藻酸盐印模。还使用Trios口内扫描仪获取全牙弓上颌和下颌的口内扫描数据。将印模灌注成石膏模型,随后使用普兰梅卡Promax锥形束计算机断层扫描(CBCT)扫描仪进行扫描。石膏模型也在桌面扫描仪(Dental Wings 7系列)中进行扫描以供参考。将CBCT设备的DICOM文件转换为stl文件。使用三维表面测量软件,将CBCT设备和口内扫描仪的stl文件与桌面扫描仪的参考文件进行准确性比较。使用SPSS软件进行统计分析。Trios的误差较小(中位数=39μm),低于CBCT(中位数=62μm),两种方式之间存在统计学显著差异(z=-4.6,p<0.005)。关于口内扫描仪,前牙的误差较小(42±16μm),而后牙的误差较大(47±16μm),差异显著(t(39)=-2.4,p=0.019)。在上颌和下颌之间或左右象限之间,口内扫描仪的平均准确性没有显著差异。与相关石膏模型的CBCT扫描相比,使用Trios口内扫描仪进行全牙弓数字化更为准确。与后牙口内扫描仪相比,前牙口内扫描仪在统计学上更准确。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验